-
Free Shipping
Orders $75 & Up
-
30-day Money Back
Guarantee*
-
100% Secure Online Shopping
SSL - Verified Merchant
EnerSys PowerSafe SBSXL-150F-FT Battery - 12V 150ah Front Terminal Telecom Power Solution

EnerSys PowerSafe SBSXL-150F-FT Battery - 12V 150ah Front Terminal Telecom Power Solution
EnerSys PowerSafe SBSXL-150F-FT Battery - 12V 150Ah Front Terminal High-Capacity Telecom Solution
Built for Extended Runtime in Temperature-Challenged Infrastructure. Your mission-critical telecommunications and energy storage systems require substantial backup capacity that performs reliably when ambient conditions exceed design parameters. The EnerSys PowerSafe SBSXL-150F-FT delivers consistent 150Ah capacity at elevated temperatures where standard batteries experience rapid degradation.
As battery specialists since 2010, we've deployed thousands of telecom backup systems where extended runtime directly determines service continuity. This precision-engineered 12V front terminal battery features EnerSys Thin Plate Pure Lead (TPPL) technology delivering 10-year service life at 95°F - designed for professionals managing macro cells, central offices, and energy storage applications where capacity fade is not acceptable.
Complete Technical Specifications
SBSXL-150F-FT Technical Data | |
---|---|
Battery Chemistry | Thin Plate Pure Lead (TPPL) |
Voltage | 12V nominal |
Capacity (US Standard) | 150Ah (8hr rate / 1.75Vpc / 77°F) |
Dimensions (L×W×H) | 22.1" × 5.92" × 5.91" (561mm × 150.4mm × 150mm) |
Weight | 111.7 lbs (50.7 kg) |
Terminal Type | M6 Front Terminal |
Internal Resistance | 4.9 milliohms |
Short Circuit Current | 2,950 Amps |
Compliance | Telcordia GR-4228 Level III, NEBS GR-63, IEC 60896-21/22 |
Model Number | SBSXL-150F-FT |
Service Life | 10 years at 95°F (35°C), 20 years at 77°F (25°C) |
Manufacturer | EnerSys (PowerSafe brand) |
High-Capacity TPPL Chemistry. Extended Runtime Capability. Proven Field Performance.
Why TPPL Technology for Extended Backup Applications
From Our Energy Storage Deployment Analysis: After reviewing thousands of high-capacity installations across telecommunications and utility sectors, we've documented critical performance requirements when extended runtime meets thermal stress.
Standard High-Capacity AGM Challenges:
- Capacity degradation accelerates above 85°F ambient conditions
- Sulfation occurs during partial state-of-charge cycling in renewable applications
- Thermal management infrastructure requires significant capital and operational expense
- Service life typically ends between years 5-7 in temperature-stressed installations
PowerSafe SBSXL-150F-FT Advantages:
- ✓ Maintains rated capacity through year 10 at 95°F operating conditions
- ✓ Handles partial state-of-charge cycling without performance degradation
- ✓ Reduces cooling infrastructure requirements and operational costs
- ✓ Achieves 20-year service life in controlled 77°F environments
When Extended Runtime Determines Service Continuity
PowerSafe SBSXL-150F-FT Batteries Excel in Critical Applications:
- Macro Cell Sites: 4G/5G base stations requiring extended backup windows, microwave transport equipment, outdoor cabinet installations with thermal challenges
- Central Office Extended Backup: Core network equipment, fiber optic terminals, regional switching centers where utility reliability is uncertain
- Energy Storage Systems: Solar/wind integration, peak shaving installations, microgrid applications requiring deep-cycle capability with long service life
- Switchgear and Substation Control: Protection systems, SCADA networks, RTU arrays where extended outage support is critical
Direct Replacement For:
EnerSys PowerSafe SBS XL series 150Ah front terminal configurations - compatible with standard telecom rectifier systems, energy storage inverters, and -48VDC infrastructure requiring extended runtime capacity
We've Documented Extended Runtime Battery Failure Patterns
- Macro Cell Outage Impact: Single site failure during utility outage affects thousands of subscribers with restoration costs including crew dispatch, generator rental, and customer credits - battery capacity fade represents the primary failure mode
- Energy Storage Investment Risk: Batteries failing before projected service life create substantial increase in levelized cost of storage, undermining renewable integration business cases and return on investment
- Critical Load Runtime Shortfall: Batteries degrading below design capacity cannot support calculated backup windows, forcing premature replacement or emergency load shedding during actual outage events
Battery specialists since 2010 serving extended runtime applications. Because calculated backup windows aren't negotiable.
Secure Professional Checkout
SSL Encrypted • PCI Compliant • High-Capacity Solutions
Questions From Our High-Capacity Battery Technical Support
Q: "Can I use SBSXL-150F-FT batteries in energy storage systems with renewable integration?"
A: Yes. The TPPL chemistry handles partial state-of-charge cycling common in solar and wind applications without sulfation damage. The 150Ah capacity provides substantial energy storage for peak shaving and load leveling. Ensure your charge controller supports the recommended 2.27Vpc float voltage with proper temperature compensation. The 10-20 year service life makes these batteries ideal for renewable installations requiring long-term reliability.
Q: "What discharge rate should I use for capacity testing?"
A: EnerSys specifies 8-hour rate (18.75A) to 1.75Vpc at 77°F for nameplate capacity verification. For faster testing, use 1-hour rate (150A) to 1.67Vpc, expecting approximately 85-90% of rated capacity. Always document actual ambient temperature during testing - results at elevated temperatures require correction factors. Capacity retention above 80% of rated confirms continued service viability.
Q: "How does the 4.9 milliohm internal resistance affect my DC system design?"
A: The exceptionally low internal resistance provides minimal voltage drop during high-current discharge events - critical for maintaining proper equipment operation throughout extended backup windows. In -48VDC systems, the low resistance enables accurate runtime calculations and prevents premature low-voltage disconnects. During float operation, reduced I²R heating contributes to the extended service life in high-temperature environments.
Q: "Why choose High-Tech Battery Solutions for EnerSys high-capacity PowerSafe batteries?"
A: As battery specialists since 2010 with extensive experience in extended runtime applications, we provide technical guidance beyond basic specifications. We assist with string sizing calculations, thermal management assessments, and capacity testing protocols specific to your application. Our batteries ship with complete documentation for Telcordia compliance, and we support customers through the entire service life with replacement planning based on actual field performance data.
Related Professional-Grade Solutions
Explore our complete telecom battery selection or view all UPS and backup power batteries.