C&D UPS12-600MR Battery
C&D UPS12-600MR Battery
C&D Dynasty UPS12-600MR Battery - 12V 147 Ah High Rate Max AGM
Warranty
Built for Short-Duration Power
- Equalize and cycle service charge voltage - 14.4 to 14.8 VDC average per 12V unit at 77°F, distinct from the float setting the rectifier normally holds.
- Top terminal, 1/4-20 UNC at 110 in-lbs - 12.4 N-m on a threaded insert, with a 0.0034 ohm reference impedance at 60 Hz.
- Flame-arresting valve in each of six cells - patented and UL recognized, inside a UL94-V2 flame retardant case and cover.
- Telecom-grade recombination behavior - C&D builds the MR to the same recombination, thermal-runaway prevention and gassing characteristics as its Bellcore 4228 compliant Dynasty Telecom line.
- Compliance set on the sheet - UL1778, UL 924, UL 1989, UL 94 V-2, BS6290-4 and IEC-896-2, on a UL-recognized component.
Technical Specifications
| C&D UPS12-600MR Specifications | |
|---|---|
| Part Number | UPS12-600MR (also searched as UPS12 600MR, UPS12600MR; sold under the C&D Dynasty brand) |
| Series | UPS High Rate Max (MR), retired by C&D, replaced by UPS12-605PLP |
| Battery Type | AGM, valve regulated lead acid (VRLA), high rate |
| Nominal Voltage | 12V (6 cells per unit) |
| Nominal Capacity | 147 Ah at the 20-hour rate to 1.75 VPC at 25°C (77°F) |
| Watts Per Cell | 601 W per cell at the 15-minute rate to 1.67 VPC at 77°F |
| Constant Power to 1.75 VPC | 868 W/cell at 5 min, 682 at 10 min, 551 at 15 min, 453 at 20 min, 345 at 30 min, 212 at 60 min, 151 at 90 min |
| Constant Power to 1.67 VPC | 969 W/cell at 5 min, 745 at 10 min, 601 at 15 min, 486 at 20 min, 361 at 30 min, 217 at 60 min, 153 at 90 min |
| Published End Points | 1.75, 1.70, 1.67 and 1.65 VPC (no 1.60 VPC column is published for this model) |
| Terminal Type | Top terminal, threaded insert, 1/4-20 UNC bolt |
| Terminal Torque | 110 in-lbs (12.4 N-m) |
| Length | 13.57 inches (344.7 mm) |
| Width | 6.80 inches (172.7 mm) |
| Height | 10.81 inches to case top (274.5 mm) |
| Total Height | 10.93 inches over terminals (277.7 mm) |
| Weight | 109 lbs (49.4 kg) |
| Short Circuit Current | 6,448 A at 0.1 second |
| Impedance | 0.0034 ohms at 60 Hz (reference figure; C&D recommends individual baselines) |
| Design Life | 10 year design life at 25°C (C&D) |
| Warranty | 3 years at 25°C (77°F) (C&D Form 41-9027, UPS High Rate Max series) |
| Minimum Order | 4 units |
Where This Battery Is Used
- High-density data center UPS modules - short ride-through at maximum kilowatts per rack foot.
- Emergency 911 response centers - dispatch consoles and radio plant that cannot drop while the generator starts.
- Hospitals and medical facilities - code-driven standby power that gets load-tested on a published schedule.
Ordering and Freight
Frequently Asked Questions
Why is the UPS12-600MR rated 147 Ah when the 540MR is 149?
Because they are tuned for different ends of the discharge curve in the same case. The 600MR carries 601 watts per cell at fifteen minutes against the 540MR's 537, and gives up two amp-hours at the twenty-hour rate to do it. At 90 minutes the order is the same as at 15: 153 watts per cell against 139. If your UPS worksheet is written in watts, the 600MR is the larger battery. If it is written in amp-hours, it reads as the smaller one.
Is there a C&D UPS12-620MR?
No. C&D's High Rate Max table lists a UPS12-600MR at 12V and a UPS6-620MR at 6V, and no 12V 620 part exists. Our own page title and meta carried UPS12-620MR, and that is corrected here. If a drawing or an old BOM in your records calls for a UPS12-620MR, the block on the shelf is almost certainly one of those two, and a specialist can tell them apart from the label photograph.
What short-circuit current should the DC protection be sized against?
6,448 amps at 0.1 second per block, from C&D's additional-data table. That is the highest figure on the High Rate Max sheet, above the 5,540 amps of the front-access 1000MRF and the 5,000 of the 540MR. Fuse and breaker interrupting ratings, and the bolted-fault study behind them, get built on the battery's figure and not on a series average.
Which end-point voltages does C&D publish for the 600MR?
Four: 1.75, 1.70, 1.67 and 1.65 volts per cell, across ten runtimes from 5 to 90 minutes. The other 12V top-terminal blocks in the line carry a fifth column at 1.60 VPC and this one does not. If your sizing sheet is written to a 1.60 end point, use the 1.65 row as the published figure and ask a specialist to confirm against C&D's sizing program.
Send the quantity, your delivery ZIP and your requested-by date. A specialist confirms availability, the warranty term, volume pricing and freight in writing, with no obligation to buy.