• Free Shipping

    Orders $75 & Up

  • 30-day Money Back

    Guarantee*

  • 100% Secure Online Shopping

    SSL - Verified Merchant

C&D Technologies UPS12-300MR Battery Replacement

$285.95
SKU: UPS12-300MR
Availability: Request Quote For Availability
Minimum Purchase: 4 units
Shipping: Free shipping on orders $75 and up
Voltage: 12
Capacity: 78.6 Ah (20-hour rate to 1.75 VPC at 25C); 300 W per cell at 15 minutes to 1.67 VPC
Chemistry: AGM VRLA, high rate, long life alloy
Terminal: Top terminal, threaded insert, 1/4-20 UNC, 110 in-lbs
Minimum Order Quantity: 4 Batteries
Dimensions: 10.27 x 6.83 x 8.01 in
C&D Technologies UPS12-300MR Battery Replacement

C&D Technologies UPS12-300MR Battery Replacement

$285.95
Adding to cart… The item has been added

C&D Dynasty UPS12-300MR Battery - 12V 78.6 Ah High Rate Max AGM

This part is retired by C&D. C&D names the UPS12-305PLP Pure Lead Plus as the replacement; we supply the UPS12-300MR while inventory holds.
A UPS ride-through is almost never exactly fifteen minutes long, and C&D publishes fifty points for the UPS12-300MR, ten runtimes at five end-point voltages, so the odd duration comes off the table. The headline ratings on this High Rate Max battery are 78.6 Ah at the 20-hour rate to 1.75 volts per cell at 25°C and 300 watts per cell at the 15-minute rate to 1.67 VPC. If your sizing worksheet asks for twenty minutes to 1.70 VPC, the answer is on the sheet and it is on this page. The case is 10.27 by 6.83 inches and the block weighs 58.4 lbs.

Warranty

Warranty. C&D's term on the UPS High Rate Max series is 3 years at 25°C (77°F), under Form 41-9027. Design life is a separate figure: 10 years at 25°C is C&D's published design life for the series. Terms are confirmed in writing with your quote.

Reading the 300MR Discharge Table

78.6 Ah and 300 watts per cell
78.6 Ah at the 20-hour rate to 1.75 VPC, 300 watts per cell at 15 minutes to 1.67 VPC, both at 25°C. Watts size the UPS, amp-hours size a slow drain.
Ten published columns, 5 to 90 minutes
546 watts per cell at 5 minutes, 385 at 10, 300 at 15, 245 at 20, 183 at 30, 106 at 60 and 75 at 90, all to 1.67 VPC at 77°F.
1/4-20 inserts at 110 in-lbs
The first model in the line to use the larger threaded insert, at 110 in-lbs (12.4 N-m), against 3,600 amps of short-circuit current.
  • Recommended maximum charging current - C20 divided by 5, which for this block's 78.6 Ah works out to 15.7 amps per unit.
  • UL-recognized component - compliant with UL1778, UL 924, UL 1989 and UL 94 V-2, and with the European BS6290-4 and IEC-896-2 references.
  • Thermally welded case-to-cover bond - a flame retardant polypropylene case and cover with no mechanical seam to seep at the joint.
  • Non-hazardous by land, sea and air - outside DOT-CFR Title 49 parts 171-189, IMDG Amendment 27, and IATA and ICAO Special Provisions A67.
  • Float charge voltage 13.65 ± 0.15 VDC - the average per 12V unit; C&D's separate equalize and cycle-service window runs 14.4 to 14.8 VDC at 77°F.

Technical Specifications

C&D UPS12-300MR Specifications
Part NumberUPS12-300MR (also searched as UPS12 300MR, UPS12300MR; sold under the C&D Dynasty brand)
SeriesUPS High Rate Max (MR), retired by C&D, replaced by UPS12-305PLP
Battery TypeAGM, valve regulated lead acid (VRLA), high rate
Nominal Voltage12V (6 cells per unit)
Nominal Capacity78.6 Ah at the 20-hour rate to 1.75 VPC at 25°C (77°F)
Watts Per Cell300 W per cell at the 15-minute rate to 1.67 VPC at 77°F
Constant Power to 1.75 VPC493 W/cell at 5 min, 360 at 10 min, 281 at 15 min, 232 at 20 min, 175 at 30 min, 103 at 60 min, 73.5 at 90 min
Constant Power to 1.70 VPC525 W/cell at 5 min, 379 at 10 min, 293 at 15 min, 240 at 20 min, 179 at 30 min, 104 at 60 min, 74 at 90 min
Constant Power to 1.67 VPC546 W/cell at 5 min, 385 at 10 min, 300 at 15 min, 245 at 20 min, 183 at 30 min, 106 at 60 min, 75 at 90 min
Terminal TypeTop terminal, threaded insert, 1/4-20 UNC bolt
Terminal Torque110 in-lbs (12.4 N-m)
Length10.27 inches (260.9 mm)
Width6.83 inches (173.4 mm)
Height7.89 inches to case top (200.3 mm)
Total Height8.01 inches over terminals (203.5 mm)
Weight58.4 lbs (26.5 kg)
Short Circuit Current3,600 A at 0.1 second
Impedance0.004 ohms at 60 Hz (reference figure; C&D recommends individual baselines)
Design Life10 year design life at 25°C (C&D)
Warranty3 years at 25°C (77°F) (C&D Form 41-9027, UPS High Rate Max series)
Minimum Order4 units

Where This Battery Is Used

  • Data center and colocation UPS strings - twenty to forty blocks in series, carrying the load to generator transfer.
  • Power generation plants - switchgear control and tripping power held on a maintained float charge.
  • Semiconductor fabs - tool and process power where the restart, not the outage, is the expensive part.

Ordering and Freight

Minimum order is 4 units. At 58.4 lbs each these ship freight pre-paid by LTL to a commercial address; a residential or limited-access delivery adds $100, which is the liftgate and access charge the carrier bills us. Send the quantity, your delivery ZIP and your requested-by date, and a specialist returns a written quote with volume pricing in 24 to 48 hours.

Frequently Asked Questions

What does a UPS12-300MR string hold at 20 and 30 minutes?

At 20 minutes, 232 watts per cell to 1.75 volts per cell or 245 to 1.67. At 30 minutes, 175 and 183. Per block that is 1,392 watts for twenty minutes and 1,050 for thirty at the 1.75 end point, so a 40-block 480 VDC string carries roughly 55.7 kW for twenty minutes. Send the UPS load and the runtime and a specialist works the count from the published row.

How should the 1/4-20 terminals be prepared before the cables go on?

Brush the lead contact faces lightly with a brass bristle brush to take off transport oxidation, then coat them with an antioxidant grease such as NO-OX-ID or NCP-2. Do the same to the cable lug face. C&D's rack guide calls for this on every connection and then a torque wrench at 110 in-lbs. Do not grease the rack rails or the case itself, because some compounds attack the plastic.

What charger ripple does C&D allow on a 300MR string?

C&D recommends 0.5 percent RMS, or 1.5 percent peak to peak, of the float charge voltage. The published maximum allowed is 1.4 percent RMS, which is 4 percent peak to peak, with maximum ripple current capped at C divided by 20 at the 20-hour rate. On this block that current cap is 3.93 amps. Ripple above the limit heats the plates and shortens the string.

What freshening charge does a new UPS12-300MR string need?

2.4 volts per cell average for 24 hours, which is 14.4 volts per 12V unit with a tolerance of plus or minus 0.50 volts. C&D calls for it when the blocks have been in storage or transit for a while, when the plant floats at the low end of the range, or when more than 24 cells sit in series. Watch that current acceptance declines and that no block runs more than 5°F off its neighbors, then move to float.

The named replacement: C&D UPS12-305PLPC&D's Pure Lead Plus successor to the 300MR, current production and carrying the longer Pure Lead Plus term.
Get the UPS12-300MR priced for your string

Send the quantity, your delivery ZIP and your requested-by date. A specialist confirms availability, the warranty term, volume pricing and freight in writing, with no obligation to buy.

Call 1-877-775-4381  ·  battery specialists, not a call center

WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov (State of California only).

Customer Reviews

Customers Also Viewed