Voltage: 12
Capacity: 78 Ah (C20, 20-hour rate to 1.75 VPC at 25C); 315.0 W per cell at 15 minutes to 1.67 VPC
Chemistry: AGM VRLA, pure lead, long-life alloy grids
Terminal: Top terminal, threaded insert, 1/4-20 UNC, 110 in-lbs
Features: Pure Lead
Dimensions: 10.3 x 6.9 x 8.0 in
C&D UPS12-305PLP Pure Lead Plus Battery

C&D UPS12-305PLP Pure Lead Plus Battery

$285.95
Adding to cart… The item has been added

C&D Dynasty UPS12-305PLP Battery - 12V 78 Ah Pure Lead Plus AGM

Three capacity figures, not one, come with the UPS12-305PLP, C&D's Pure Lead Plus block in place of the retired UPS12-300MR: 74 Ah at the 8-hour rate and 78 Ah at the 20-hour rate, both to 1.75 volts per cell at 25°C, plus 69 Ah at the 10-hour rate to 1.80 VPC at 20°C. Take the wrong column into a sizing sheet and the string comes out short. The 20-hour figure is the one that lines up against a legacy amp-hour spec. The block is 58 lbs on a 261 by 174 mm case with 1/4-20 UNC inserts.

Warranty

Warranty. C&D's term on the Pure Lead Plus series is 5 years at 30°C (86°F), under C&D's Pure Lead Plus limited warranty (2021). Design life is a separate figure: C&D publishes a 12+ year design life at 25°C (77°F) for the series. Terms are confirmed in writing with your quote.

Three Published Capacity Bases

78 Ah at the 20-hour rate
3.9 amps for twenty hours to 1.75 volts per cell at 25°C. This is the column that compares straight across to an older amp-hour rating.
74 Ah at the 8-hour rate
9.3 amps for eight hours to 1.75 VPC at 25°C. Reserve calculations on switchgear and telecom plant usually run on this one.
69 Ah at the 10-hour rate
To 1.80 VPC at 20°C. A cooler ambient and a higher end point are why this number sits below the other two on the same battery.
  • MSE advanced paste processing - C&D's proprietary paste process puts more of the active material to work, which is what holds float current down across a long standby life.
  • Helium leak tested case-to-cover bond - the case and cover are thermally welded, then leak tested with helium before the block leaves the line.
  • UL 1778 and UL 1989 compliance - the UPS and stationary battery standards, with UL 924 and UL 94 V-2 also listed for the Pure Lead Plus series.
  • No fixed mounting orientation - C&D clears the block for service in any position, so tray layout stays a mechanical decision and the battery puts no constraint on it.
  • Two years on the shelf at 77°F - C&D rates the series for storage up to 24 months at +77°F (+25°C) with minimum upkeep before a freshening charge is called for.

Technical Specifications

C&D UPS12-305PLP Specifications
Part NumberUPS12-305PLP (also searched as UPS12 305PLP, UPS12305PLP; replaces UPS12-300MR; sold under the C&D Dynasty brand)
SeriesPure Lead Plus (PLP), top terminal
Battery TypeAGM, valve regulated lead acid (VRLA), pure lead
Nominal Voltage12V (6 cells per unit)
Capacity, C2078 Ah at the 20-hour rate to 1.75 VPC at 25°C (77°F)
Capacity, C874 Ah at the 8-hour rate to 1.75 VPC at 25°C
Capacity, C1069 Ah at the 10-hour rate to 1.80 VPC at 20°C
Constant Power, 15 minutes315.0 W per cell to 1.67 VPC at 77°F; 293.9 W per cell to 1.75 VPC
Constant Power to 1.67 VPC900.0 W/cell at 1 min, 571.3 at 5 min, 393.8 at 10 min, 315.0 at 15 min, 249.4 at 20 min, 185.8 at 30 min, 135.0 at 45 min, 106.2 at 60 min
Constant Power to 1.75 VPC515.5 W/cell at 5 min, 362.4 at 10 min, 293.9 at 15 min, 235.0 at 20 min, 177.4 at 30 min, 130.5 at 45 min, 103.4 at 60 min
Constant Current to 1.75 VPC53.1 A for 1 hour, 14.0 A for 5 hours, 9.3 A for 8 hours, 7.5 A for 10 hours, 3.9 A for 20 hours
Short Circuit Current3,600 A at 0.1 second
Terminal TypeTop terminal, threaded insert, 1/4-20 UNC
Terminal Torque110 in-lbs (12.4 N-m)
Length261 mm (10.3 inches)
Width174 mm (6.9 inches)
Height200 mm (7.9 inches)
Total Height203 mm (8.0 inches) over terminals
Weight58 lbs (26.3 kg)
Design Life12+ years at 25°C (77°F) (C&D)
Warranty5 years at 30°C (86°F) (C&D Pure Lead Plus limited warranty, 2021)
Minimum Order4 units

Where This Battery Is Used

  • Racks built around a retired MR block - cabinets originally specified for the UPS12-300MR, on the same class of footprint.
  • Building life-safety panels - fire alarm, egress lighting and elevator control held up through a transfer.
  • Municipal and campus data rooms - single-module UPS plant where the ride-through is counted in minutes.

Ordering and Freight

Minimum order is 4 units. Each block weighs 58 lbs, and a set ships freight pre-paid by LTL to a commercial address; a residential or limited-access delivery adds $100, which is the liftgate and access charge the carrier bills us. Send the quantity, your delivery ZIP and your requested-by date, and a specialist returns a written quote with volume pricing in 24 to 48 hours.

Frequently Asked Questions

Which of the three capacity figures belongs on a UPS sizing worksheet?

Usually none of them. A UPS sizing table asks for watts per cell over a runtime, and for this block that is 315.0 watts per cell at fifteen minutes to 1.67 volts per cell, or 293.9 to 1.75. The amp-hour columns come in when the load is a steady low current held over hours: 9.3 amps for eight hours, 3.9 amps for twenty. Send the load in kilowatts and the runtime you have to hold, and a specialist works the block count off the published row.

Why is the 10-hour figure lower than the 8-hour figure?

Because it is measured differently. C&D's C10 column ends at 1.80 volts per cell and is taken at 20°C, while C8 and C20 end at 1.75 VPC at 25°C. A higher end point stops the discharge sooner and a cooler battery gives up less, so 69 Ah at C10 and 74 Ah at C8 describe the same battery under two sets of conditions. Compare figures only against the same rate, end point and temperature.

How much does a four-block UPS12-305PLP shelf weigh?

232 lbs of battery. Each unit is 58 lbs (26.3 kg), and four of them make a 48V string. Add the rack, the tray and the interunit connectors before checking the shelf rating, and remember the load sits on a 261 by 174 mm footprint per block and is not spread across the shelf.

How does the UPS12-305PLP compare with the UPS12-355PLP?

The 355PLP is one step up in every direction: 94 Ah at the 20-hour rate against 78, 365.5 watts per cell at fifteen minutes against 315.0, and a 306 mm case against 261 mm, at 173 mm wide against 174. It weighs 67 lbs against 58. If the tray has 45 mm of length to spare, the 355PLP buys roughly twenty percent more capacity on the same terminal hardware.

Next rating up: C&D UPS12-355PLP94 Ah at the 20-hour rate and 365.5 watts per cell at fifteen minutes, on a case 45 mm longer and 1 mm narrower.
Get the UPS12-305PLP priced for your string

Send the quantity, your delivery ZIP and your requested-by date. A specialist confirms availability, the warranty term, volume pricing and freight in writing, with no obligation to buy.

Call 1-877-775-4381  ·  battery specialists, not a call center

WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov (State of California only).

Customer Reviews

Customers Also Viewed