C&D Technologies UPS12-100MR Battery
C&D Technologies UPS12-100MR Battery
C&D Dynasty UPS12-100MR Battery - 12V 26 Ah High Rate Max AGM
Warranty
The Small End of the High Rate Max Line
- Top terminal, 10-32 UNF - torqued to 40 in-lbs (4.5 N-m) on C&D's data table, against 1,750 amps of short-circuit current at 0.1 second.
- UL-recognized component - built to comply with UL1778, UL 924, UL 1989 and UL 94 V-2, and with BS6290-4 and IEC-896-2.
- Flame-arresting vent in every cell - a patented UL-recognized valve per cell, inside a thermally welded case-to-cover bond that eliminates leakage.
- AGM recombination up to 99% - absorbent glass mat construction, so the block takes no water over its service life.
- Float charge voltage 13.65 ± 0.15 VDC - the average per 12V unit that the rectifier gets set against.
Technical Specifications
| C&D UPS12-100MR Specifications | |
|---|---|
| Part Number | UPS12-100MR (also searched as UPS12 100MR, UPS12100MR; sold under the C&D Dynasty brand) |
| Series | UPS High Rate Max (MR), retired by C&D |
| Battery Type | AGM, valve regulated lead acid (VRLA), high rate |
| Nominal Voltage | 12V (6 cells per unit) |
| Nominal Capacity | 26 Ah at the 20-hour rate to 1.75 VPC at 25°C (77°F) |
| Watts Per Cell | 90.9 W per cell at the 15-minute rate to 1.67 VPC at 77°F |
| Constant Power to 1.75 VPC | 157 W/cell at 5 min, 114 at 10 min, 87.5 at 15 min, 72.1 at 20 min, 54.9 at 30 min, 33.7 at 60 min, 24 at 90 min |
| Constant Power to 1.67 VPC | 172 W/cell at 5 min, 117 at 10 min, 90.9 at 15 min, 75.4 at 20 min, 57.2 at 30 min, 34.1 at 60 min, 24.6 at 90 min |
| Terminal Type | Top terminal, threaded insert, 10-32 UNF |
| Terminal Torque | 40 in-lbs (4.5 N-m) |
| Length | 6.54 inches (166.2 mm) |
| Width | 5.17 inches (131.3 mm) |
| Height | 6.37 inches to case top (161.7 mm) |
| Total Height | 6.86 inches over terminals (174.3 mm) |
| Weight | 21 lbs (10 kg) |
| Short Circuit Current | 1,750 A at 0.1 second |
| Impedance | 0.006 ohms at 60 Hz (C&D publishes this for reference; take your own baseline) |
| Operating Temperature | Discharge -40°F (-40°C) to +160°F (+71°C); charge -10°F (-23°C) to +140°F (+60°C) |
| Design Life | 10 year design life at 25°C (C&D) |
| Warranty | 3 years at 25°C (77°F) (C&D Form 41-9027, UPS High Rate Max series) |
| Minimum Order | 4 units |
Where This Battery Is Used
- Small rack UPS cabinets - four blocks for 48V or ten for 120V, on a shelf cut too shallow for the 300MR class.
- Emergency 911 response centers - console and radio power held up long enough for the generator to pick up.
- Testing laboratories - instrument racks where an unplanned shutdown costs a whole run.
Ordering and Freight
Frequently Asked Questions
How many UPS12-100MR blocks make a 48V string?
Four. Each unit is a nominal 12V built from six cells, so four in series give 48V, ten give 120V and twenty give 240V. C&D's own installation guide puts typical system voltages between 12 and 480 VDC, with 72 to 480 VDC the usual data center UPS range. Tell a specialist the string voltage and the runtime you need and the block count comes off the published power table rather than an estimate.
What torque do the 10-32 UNF terminals take?
40 in-lbs (4.5 N-m), from C&D's additional-data table for this model. Under-torque shows up first as a rising ohmic reading at the connection and only later as heat. Before the cables go on, brush the lead contact faces with a brass bristle brush and coat them with an antioxidant grease such as NO-OX-ID or NCP-2, which is what C&D's rack installation guide calls for.
Can the UPS12-100MR be mounted on its side?
Yes. C&D states the High Rate Max blocks can be operated in any orientation, and recommends upright, side or end mounting. Leave half an inch between units on the shelf so the interunit cables line up with the adjacent terminals and air can move between the cases. In a sealed enclosure, confirm the cabinet and the room are ventilated.
How long can a UPS12-100MR sit before it needs a charge?
Up to six months at 77°F (25°C) before a freshening charge is required. Stored warmer than that, it needs recharging sooner. C&D covers the detail in brochure 41-7272 on self-discharge and inventory control, and the installation guide sets the freshening charge at 2.4 volts per cell average for 24 hours. If the batteries have been on a shelf for a while, say so on the quote request and a specialist notes the date code.
Send the quantity, your delivery ZIP and your requested-by date. A specialist confirms availability, the warranty term, volume pricing and freight in writing, with no obligation to buy.
Call 1-877-775-4381 · battery specialists, not a call centerWARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov (State of California only).