Leoch XP12-350FR High Rate AGM Battery
Leoch XP12-350FR Battery - 12V High Rate AGM, 350 W/Cell
Warranty
More Power in the Same Cross-Section
- UL 94 V-0 flame-retardant case - the FR build that occupied-building specifications require.
- Factory capacity-tested before shipment - each unit proves its discharge before it is boxed.
- UL recognized, IEC 60896-21 and -22 compliant, IATA air-freight approved - certified for the site file and flyable when the clock matters.
Technical Specifications
| Leoch XP12-350FR Specifications | |
|---|---|
| Part Number | XP12-350FR (also searched as xp12-350, leoch xp12-350) |
| Battery Type | High-rate AGM VRLA, UPS standby service |
| Nominal Voltage | 12V |
| 15-Minute Rating | 350 watts per cell to 1.67 VPC at 77°F |
| Nominal Capacity | 95 Ah at the 20-hour rate to 1.80 VPC |
| Terminal Type | M6 threaded insert (Leoch T6) |
| Length | 12.05 inches (306 mm) |
| Width | 6.61 inches (168 mm) |
| Height | 8.19 inches (208 mm); 8.31 inches over terminals |
| Weight | 62.2 lbs (28.2 kg) |
| Case | Flame retardant, UL 94 V-0 |
| Operating Temperature | Discharge -15°C to +50°C (5°F to 122°F) |
| Design Life | 12 years at 77°F (Leoch) |
| Warranty | 36 months in UPS service (Leoch) |
Where This Battery Is Used
- Growing UPS installations - server rooms whose DC bus load has outrun the string that was sized five years ago.
- Hospital and lab power quality systems - loads where the transfer window is non-negotiable.
- Telecom power plants - high-rate bridging in front of the generator at switch sites.
- Modular data-center rows - dense strings where every inch of tray earns its keep.
Ordering and Freight
Frequently Asked Questions
When is the XP12-350FR the right pick over the XP12-300FR?
When the runtime math says so. Both share the 6.61 by 8.19 inch cross-section; the 350 is 1.8 inches longer, 8.8 lbs heavier and carries 50 more watts per cell over the 15-minute window. If your string is riding close to its low-voltage cutoff at today's load, the 350 restores margin without changing the tray height. Send the DC bus load and we will run the numbers both ways.
Can I mix XP12-350FR and XP12-300FR units in one string?
No. A series string discharges through every unit equally, and mismatched models drag the string to the weaker unit's curve while overworking it. Replace a string with one model, one age, one lot where possible. If you are expanding, quote the whole string rather than topping up.
Is 95 Ah the number I should size runtime on?
Not for UPS work. The 95 Ah is a 20-hour figure, and a UPS discharge is 5 to 30 minutes. Size on the 15-minute watts-per-cell rating at your end voltage. The amp-hour figure matters mostly for comparing physical battery classes and for long, low-rate duties this unit is not usually bought for.
Does it need a ventilated cabinet?
It is a sealed VRLA that recombines gas internally in normal service, so it lives in equipment rooms and enclosed cabinets rather than battery rooms. Enclosures still need the modest airflow every VRLA installation calls for, and your AHJ or facility specification governs. Ask the specialist to include the installation guidance with your quote if the enclosure is tight.
Send the quantity, your delivery ZIP and your requested-by date. A specialist confirms availability, the warranty term, volume pricing and freight in writing, with no obligation to buy.