Leoch XP12-300FR High Rate AGM Battery
Leoch XP12-300FR Battery - 12V High Rate AGM, 300 W/Cell
Warranty
Built for the First Fifteen Minutes
- 100% initial capacity tested - every unit is discharge-tested before it leaves the factory.
- UL recognized, IEC 60896-21 and -22 third-party tested - certification you can hand to the site auditor.
- IATA approved for air freight - sealed and non-spillable, it can fly when a UPS is down and waiting.
Technical Specifications
| Leoch XP12-300FR Specifications | |
|---|---|
| Part Number | XP12-300FR (also searched as xp12-300, leoch xp12-300) |
| Battery Type | High-rate AGM VRLA, UPS standby service |
| Nominal Voltage | 12V |
| 15-Minute Rating | 300 watts per cell to 1.67 VPC at 77°F |
| Nominal Capacity | 82 Ah at the 20-hour rate to 1.80 VPC |
| Terminal Type | M6 threaded insert (Leoch T6) |
| Length | 10.24 inches (260 mm) |
| Width | 6.61 inches (168 mm) |
| Height | 8.19 inches (208 mm); 8.31 inches over terminals |
| Weight | 53.4 lbs (24.2 kg) |
| Case | Flame retardant, UL 94 V-0 |
| Operating Temperature | Discharge -15°C to +50°C (5°F to 122°F) |
| Design Life | 12 years at 77°F (Leoch) |
| Warranty | 36 months in UPS service (Leoch) |
Where This Battery Is Used
- Three-phase UPS strings - data-center and hospital systems sized in watts per cell, not amp hours.
- Network operations centers - the bridge load between mains failure and generator pickup.
- Emergency power and egress systems - code-driven backup in occupied buildings, where the V-0 case is specified.
- Industrial process control - rides through the sags and transfers that would otherwise crash a line.
Ordering and Freight
Frequently Asked Questions
What does the 300 in XP12-300FR mean?
Watts per cell over a 15-minute discharge to 1.67 volts per cell. It is not an amp-hour figure. A 12-volt battery has six cells, so one XP12-300FR supports about 1,800 watts for 15 minutes to that end voltage. UPS strings are sized on this number because the job is minutes of full power, not hours of trickle.
What does the FR suffix mean?
The flame-retardant case build: the ABS case and covers are rated UL 94 V-0. Facility specifications for occupied buildings, data centers and telecom rooms commonly require the rating, and this page sells the FR build.
Why does an 82 Ah battery replace units labeled with bigger numbers?
Because high-rate batteries are bought for their 15-minute power, not their 20-hour capacity. Two batteries with the same amp-hour label can differ sharply in how much of it they deliver in 15 minutes. Compare watts per cell at your runtime and end voltage, and send us the label of the unit you are replacing if you want the comparison done for you.
How fast does it recharge after a discharge?
Recharge time depends on your charger's current limit and the depth of the discharge, so we do not quote a single figure. As a working rule, a UPS string is back in the high nineties of capacity after a day on the rectifier's normal recharge setting. If your site has a short generator-test interval, tell the specialist and we will check the duty against the line.
Send the quantity, your delivery ZIP and your requested-by date. A specialist confirms availability, the warranty term, volume pricing and freight in writing, with no obligation to buy.
Call 1-877-775-4381 · battery specialists, not a call centerWARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov (State of California only).