• Free Shipping

    Orders $75 & Up

  • 30-day Money Back

    Guarantee*

  • 100% Secure Online Shopping

    SSL - Verified Merchant

Leoch XP12-210FR High Rate AGM Battery

$169.95
SKU: XP12-210FR
Availability: Request Quote For Availability
Shipping: Free shipping on orders $75 and up
Voltage: 12
Capacity: 55 Ah (20-hour rate to 1.80 VPC at 25C); 210 W per cell (15-min to 1.67 VPC)
Chemistry: High rate AGM VRLA (UPS standby)
Terminal: M6 threaded insert (Leoch T6)
Dimensions: 9.02 x 5.43 x 7.99 in (L x W x total H); 229 x 138 x 203 mm
Design Life: 12 years at 25C on float (Leoch)
Features: High rate AGM, 1,262 A short circuit, 5 mOhm, -15C to 50C discharge, UL 94 V-0 FR case, IEC 60896-21/22, 36-month Leoch UPS term
Group Size: Not published by Leoch; 229 x 138 mm XP case
Leoch XP12-210FR High Rate AGM Battery

Leoch XP12-210FR High Rate AGM Battery

$169.95
Adding to cart… The item has been added

Leoch XP12-210FR Battery - 12V 210 W per Cell High Rate AGM, 55Ah, M6

The XP12-210FR delivers 210 watts per cell over 15 minutes to 1.67 volts per cell, about 1,260 watts from the 12 volt block, with 55 Ah at the 20-hour rate. The case is 229 by 138 mm and 203 mm to the top of the M6 terminals (9.02 by 5.43 by 7.99 inches) at 17.7 kg (39.0 lbs), a size that one person can still lift into a tray. The FR in the part number is the UL 94 V-0 flame retardant case build. Leoch's XP plates are drawn for the short heavy discharge a UPS asks for: the 5-minute row of the table reaches 237.5 amps, and the internal resistance is about 5 milliohms. Design life is 12 years at 25°C on float. This is the most searched part in the small XP range, and it is quoted in sets of six or more.

Warranty

Warranty. Leoch warrants the XP line for 36 months in UPS service. Design life is a separate figure: 12 years at 25°C (77°F) on float, from the XP12-210 datasheet, and it is not a warranty period. Terms are confirmed in writing with your quote.

Fifty-Five Amp Hours Built for Fifteen Minutes

210 watts per cell at 15 minutes
About 1,260 watts from one block to 1.67 volts per cell, and 443.8 watts per cell at the 5-minute point, more than double the 15-minute figure.
5 milliohms, 1,262 amps short circuit
Low internal resistance is what lets a 55 Ah block hold its voltage at 237 amps. It is also the figure the DC-side breaker coordination needs.
UL 94 V-0 case
The FR build. Leoch lists UL 94 HB as the standard XP case and V-0 as the option; this page sells the V-0 option that occupied-building and data room specifications call for.
  • 237.5 amps for 5 minutes - to 1.67 volts per cell, with 127.0 amps at 15 minutes, 73.1 amps at 30 minutes and 39.5 amps for a full hour.
  • 55 Ah at the 20-hour rate - to 1.80 volts per cell at 25°C, 2.75 amps for 20 hours, for the rare site that runs it as a long-duration reserve.
  • 39.0 lbs, one-person lift - the largest XP block that goes into a tray without two people or a lift table.
  • Virgin lead plates, copper alloy inserts - low resistance at the plates and the posts, so the voltage holds under load instead of sagging into the inverter's cutoff.
  • IATA approved for air freight - sealed and non-spillable, it can fly when a UPS is down and waiting.

Technical Specifications

Leoch XP12-210FR Specifications
Part NumberXP12-210FR (also written XP12-210, XP12 210, xp12-210fr and leoch xp12-210)
SeriesLeoch XP, ultra high rate AGM for UPS, flame retardant (FR) case build
Battery TypeHigh rate AGM, valve regulated lead acid (VRLA), UPS standby service
Nominal Voltage12V (6 cells)
Nominal Rating, 15 Minutes210 W per cell to 1.67 VPC at 25°C (1,260 W per battery)
Capacity, 20-Hour Rate55 Ah to 1.80 VPC at 25°C
Discharge Current, 5 Minutes237.5 A to 1.67 VPC; 175.1 A to 1.80 VPC
Discharge Current, 15 Minutes127.0 A to 1.67 VPC; 102.4 A to 1.80 VPC
Discharge Current, 30 Minutes73.1 A to 1.67 VPC; 64.2 A to 1.80 VPC
Discharge Current, 1 Hour39.5 A to 1.67 VPC; 35.9 A to 1.80 VPC
Discharge Power, 5 Minutes443.8 W per cell to 1.67 VPC
Discharge Power, 1 Hour77.1 W per cell to 1.67 VPC
Short Circuit Current1,262.4 A
Internal ResistanceApproximately 5 milliohms, fully charged, at 25°C
Maximum Charge Current0.25C (13.75 A) at 25°C
Float Charge Voltage2.25 to 2.30 V per cell at 25°C (13.5 to 13.8 V per battery)
Equalization Charge Voltage2.30 to 2.40 V per cell at 25°C
Temperature Coefficient-3 mV per cell per °C on float; -4 mV per cell per °C on equalize
Terminal TypeM6 threaded insert (Leoch T6)
Length229 mm (9.02 inches)
Width138 mm (5.43 inches)
Container Height200 mm (7.87 inches)
Total Height203 mm (7.99 inches)
Weight17.7 kg (39.0 lbs)
Operating TemperatureDischarge -15°C to 50°C (5°F to 122°F); charge -20°C to 40°C (-4°F to 104°F); storage -15°C to 40°C (5°F to 104°F)
Capacity vs Temperature106% at 40°C; 100% at 25°C; 86% at 0°C
Self Discharge3% per month or less at 25°C
Container MaterialABS, flame retardant to UL 94 V-0 (the FR build; UL 94 HB is Leoch's standard case)
StandardsIEC 60896-21 and -22, third party tested; UL recognized; CE; IATA approved for air freight; IATF 16949 plants
Design Life12 years at 25°C on float service (Leoch)
Warranty36 months in UPS service (Leoch, XP)

Where This Battery Is Used

  • Rack and tower UPS, 5 to 10 kVA - the server room systems and external battery cabinets whose trays were drawn around a 9 by 5.4 inch block with M6 hardware.
  • Hospitals and testing laboratories - both are on Leoch's XP application list: equipment that must ride through a transfer without a reset or a lost run.
  • Telecommunications and data closets - the DC backup behind switching and edge equipment in occupied buildings, where the V-0 case rating is specified.

Ordering and Freight

Sold in a minimum of six units. Six XP12-210FR come to about 234 lbs and ship on a pallet by LTL freight; a residential or limited-access address adds $100 for the liftgate and access charge the carrier passes through. Send the quantity, your delivery ZIP and your requested-by date. A specialist confirms availability, lead time, volume pricing and freight in writing in 24 to 48 hours.

Frequently Asked Questions

What warranty applies, and is the 12-year figure part of it?

Leoch warrants the XP line for 36 months in UPS service. The 12 years is design life, Leoch's estimate of float service at 25°C from the XP12-210 datasheet, and it carries no replacement commitment. Both figures appear on this page, always labeled, because a listing that runs them together is how a buyer ends up believing in a 12-year warranty. The term is confirmed in writing with your quote.

What does the 210 in XP12-210FR stand for?

Watts per cell over a 15-minute discharge to 1.67 volts per cell at 25°C. Leoch names every XP part by this rating rather than by amp hours because the range exists for UPS duty, and a UPS is sized on power over minutes. Six cells make about 1,260 watts from one block for 15 minutes. The 55 Ah figure, at the 20-hour rate, is on the sheet as well, and it is the number to use only if the block is asked to run a long, light load.

How do I turn the watts per cell into a runtime for my UPS?

Take the UPS's DC bus load in watts, or the AC load divided by the inverter efficiency, and divide it by the number of blocks in the string times six cells. That gives the watts per cell each block must supply. Read down the constant power table to find where that figure sits: at 15 minutes this block gives 210 watts per cell, at 30 minutes 140.6, at one hour 77.1. If the load per cell is above the 15-minute figure, the runtime is shorter than 15 minutes and the 5- and 10-minute rows apply. A specialist will run the calculation from the UPS model if you would rather not.

Should I move up to the XP12-300FR instead?

Only if the tray takes it. The XP12-300FR is 260 by 168 mm and 211 mm tall at 24.2 kg, a wider and longer block, so it will not fit a tray drawn for the XP12-210FR's 229 by 138 mm footprint. If the tray does fit the larger block, the step from 210 to 300 watts per cell runs the same load about 40 percent longer. If it does not, extra runtime comes from adding strings in parallel rather than a bigger block, and the quote can price either way.

Next rating up: Leoch XP12-300FR300 watts per cell and 82 Ah in a 260 by 168 by 211 mm case at 53.4 lbs, same M6 insert.
Replacing an XP12-210FR string?

Send the UPS model, the quantity and your delivery ZIP. A specialist confirms the 229 by 138 mm footprint against the tray, checks the M6 hardware, and quotes the set with lead time and freight in writing.

Call 1-877-775-4381  ·  battery specialists, not a call center

WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov (State of California only).

Customer Reviews