EnerSys DataSafe 12HX300-FR Battery | 12V 284WPC AGM | Telecom

$269.95
SKU: 12HX300FR
Availability: Request Quote For Availability
Minimum Purchase: 4 units
Shipping: Free shipping on orders $75 and up
Voltage: 12
Chemistry: AGM
Terminal: Threaded Insert
Capacity: 70 AH
Minimum Order Quantity: 4 Batteries
EnerSys DataSafe 12HX300-FR Battery | 12V 284WPC AGM | Telecom

EnerSys DataSafe 12HX300-FR Battery | 12V 284WPC AGM | Telecom

$269.95
Adding to cart… The item has been added

EnerSys DataSafe 12HX300-FR Battery - 12V 71Ah 284 WPC UPS AGM

The 12HX300-FR is the mid-range block in EnerSys's DataSafe HX top-terminal family: 12V, 71 Ah at the 8-hour rate, and 284 watts per cell at the 15-minute rate to 1.67 volts per cell, the figure UPS runtime calculations are built on. At 60 lbs in a 10.2 by 6.9 by 8.2 inch case, it is the smallest of the large-case HX models, sharing their M6 threaded receptacles, compression grommet seals and the wider -22 degrees F operating floor.

Warranty

Warranty. Four years in float service is EnerSys's published term for the DataSafe HX range, this model included. Design life is separate: 10 years in standby is EnerSys's estimate for the series. Terms are confirmed in writing with your quote.

The Entry to the Big-Case HX Range

284 watts per cell
At the 15-minute rate to 1.67 VPC, with 513 watts per cell available at the 5-minute rate to 1.75.
71 Ah in a 60 lb case
One installer places it, which the 505 and 540 up the range cannot claim.
3,175 A short-circuit current
With 3.9 milliohms of internal resistance, the fault envelope breaker sizing works against.
  • Sealed AGM VRLA, non-spillable - gas recombination construction, approved for transport as non-hazardous per IATA Special Provision A67 and 49 CFR.
  • UL File MH12544 - with a UL94 flame-retardant container built to meet UL 1778.
  • -22°F operating floor - the wider window the 12HX205-FR through 12HX540-FR band carries.
  • Zone 4 cabinet program - EnerSys certifies HX battery cabinets to UBC Zone 4 and IBC 2012 seismic criteria.

Technical Specifications

EnerSys DataSafe 12HX300-FR Specifications
Part Number12HX300-FR (also searched as 12HX300, HX300, 12 HX 300)
Battery TypeAGM VRLA, top terminal, UPS float service
Nominal Voltage12V
Capacity, 8-hour rate71 Ah to 1.75 VPC at 77°F
Rated Power, 15-minute rate284 watts per cell to 1.67 VPC at 77°F
Power, 5-minute rate513 watts per cell to 1.75 VPC
Short Circuit Current3,175 A
Internal Resistance0.0039 ohm (reference value)
Terminal TypeM6 brass threaded receptacle, torque 60 in-lbs (6.8 N-m) ±5%
Length10.2 inches (259 mm)
Width6.9 inches (175 mm)
Height, including terminal8.2 inches (208 mm)
Weight60 lbs (27.2 kg)
Operating Temperature-22°F to +122°F (-30°C to +50°C)
Float Charging Voltage2.25 to 2.28 volts per cell at 77°F
StorageUp to 6 months at 77°F before a freshening charge is required
ListingsUL File MH12544; UL94 flame-retardant case
Design Life10 years in standby service (EnerSys estimate)
Warranty4 years in float service (EnerSys)

Where This Battery Is Used

  • Three-phase UPS strings - the 15-minute class reserve behind server rooms and critical loads.
  • Compact high-power plants - installs sized in watts per cell where floor space is tight.
  • Seismic cabinet installs - sites specifying the certified HX cabinet and rack program.

Ordering and Freight

At 60 lbs per unit, string orders ship freight pre-paid by LTL to commercial addresses; a residential or limited-access delivery adds $100, which is the liftgate and access charge the carrier bills us. Send the quantity, your delivery ZIP and your requested-by date, and a specialist returns a written quote with volume pricing in 24 to 48 hours.

Frequently Asked Questions

Is the 12HX300 a 70 Ah or 71 Ah battery?

EnerSys's current range summary publishes 71 Ah at the 8-hour rate to 1.75 volts per cell; size from that figure. Older literature carried a 70 Ah rounding, and it survives in some listings, this page's address among them. One amp hour changes no sizing decision in this class, and UPS work sizes from the 284 watts per cell at the 15-minute rate in any case.

Can I step up to the 12HX330 later for more runtime?

Only as a full string swap, and only if the tray allows it: the 330 runs 11.8 inches long against this model's 10.2, an inch and a half a packed shelf may not have. It buys 83 Ah and 336 watts per cell against 71 and 284. If growth is on the roadmap, measure for the larger case now and quote both models; carrying the extra length from day one costs less than rebuilding shelves later.

What float voltage does an HX string want?

EnerSys publishes 2.25 to 2.28 volts per cell at 77°F, which is 13.5 to 13.68 per 12V bloc, and the HX design also accepts recharge at high current rates after a discharge. Confirm the UPS's float setpoint lands in that window at commissioning and temperature-compensate where the equipment supports it. A string floated outside the published band ages faster than any spec sheet predicts.

One step up in the rangeThe 12HX330-FR carries 83 Ah and 336 watts per cell in a longer case.