• Free Shipping

    Orders $75 & Up

  • 30-day Money Back

    Guarantee*

  • 100% Secure Online Shopping

    SSL - Verified Merchant

CSB XTV 121100 Group 31 AGM 12V Extreme Temperature Battery

$314.95
SKU: XTV121100
Availability: Request Quote For Availability
Shipping: Free shipping on orders $75 and up
Voltage: 12
Capacity: 110 Ah (20-hour rate to 1.75 VPC at 25C); 2,418 W per battery (15-min to 1.67 VPC, series tables)
Chemistry: AGM VRLA, pure lead construction
Terminal: I2 threaded insert, M6 bolt, 44.9 +/- 9.0 lbf-in
Features: Extreme temperature, -20C to 50C discharge, float service outdoors, 800 A discharge ceiling, 4-year CSB term
Dimensions: 13.50 x 6.69 x 8.54 in (L x W x H)
Design Life: Up to 12 years standby at 25C; Eurobat 20C greater than 12 years
Group Size: 31
CSB XTV 121100 Group 31 AGM 12V Extreme Temperature Battery

CSB XTV 121100 Group 31 AGM 12V Extreme Temperature Battery

$314.95
Adding to cart… The item has been added

CSB XTV121100 Battery - 12V 110Ah Extreme Temperature AGM, Group 31

The XTV121100 is the largest block CSB builds in the extreme temperature range: 110 amp hours at the 20 hour rate in a group 31 case, 75.38 lbs, on I2 alloy inserts taking M6 bolts. It has the lowest internal resistance in the range at approximately 3.60 milliohms, the highest short circuit current at 2,648 amps, and it delivers 2,418 watts per battery over 15 minutes to 1.67 volts per cell. What it does not have is a higher discharge ceiling than the two blocks below it; all three of the largest XTV parts publish 800 amps for 5 seconds, because that number belongs to the terminal. Built in Taiwan with a four year term, rated to discharge from -20°C to 50°C, with a design life of up to 12 years in standby service at 25°C, it is the block a 48 volt outdoor string specifies when the hold time calculation needs the most margin a group 31 tray can carry.

Warranty

Warranty. CSB gives 4 years on the XTV parts built in Taiwan, and this is the largest of them. Design life is a separate figure: up to 12 years in standby service at 25°C (77°F), and greater than 12 years on the Eurobat 20°C basis. Country of origin is Taiwan. Terms are confirmed in writing with your quote.

The Top of the Range

110 Ah at the 20 hour rate
To 1.75 volts per cell at 25°C, with 102 Ah at the 8 hour rate and 77.5 amps sustained for one hour.
3.60 milliohms
The lowest internal resistance CSB publishes for an XTV block, and the day-one baseline for a conductance program.
2,648 amps short circuit
For 5 seconds, the highest in the range and the figure a DC protection study must clear before the string is energized.
  • 2,418 watts per battery at 15 minutes - to 1.67 volts per cell from the CSB series tables, and 19.9 amps sustained across a five hour hold.
  • 800 amps maximum discharge for 5 seconds - the same ceiling as the 80 Ah and 100 Ah blocks, set by the I2 insert and not by size.
  • 33 amps maximum charge current - the highest recharge ceiling in the range, which a cabinet rectifier will rarely reach.
  • Group 31 case at 13.50 by 6.69 by 8.54 inches - 1.35 inches longer than the group 27 XTV121000 and about 9 lbs heavier, on the same terminal hardware.
  • Build time is the factory's - the CSB price list marks the part non-stock, and the quote states the Taiwan lead time rather than assuming one.

Technical Specifications

CSB XTV121100 Specifications
Part NumberXTV121100 (also written XTV 121100, XTV-121100 and xtv121100)
SeriesXTV, Extreme Temperature, 12 volt top terminal
Battery TypeAGM, valve regulated lead acid (VRLA), pure lead construction
Nominal Voltage12V
Capacity, 20 Hour Rate110 Ah to 1.75 VPC at 25°C (CSB price list lists 110 Ah)
Capacity, 8 Hour Rate102 Ah to 1.75 VPC; 101 Ah to 1.80 VPC
Watts Per Battery, 15 Minutes2,418 W to 1.67 VPC at 25°C (CSB XTV series tables, RA240531)
Discharge Current, 60 Minutes77.5 A to 1.67 VPC at 25°C
Discharge Current, 5 Hours19.9 A to 1.67 VPC at 25°C
Maximum Charge Current33 A
Maximum Discharge Current800 A for 5 seconds
Short Circuit Current2,648 A for 5 seconds
Internal ResistanceApproximately 3.60 milliohms
Terminal TypeI2 threaded lead alloy insert to accept an M6 bolt
Terminal Torque44.9 ± 9.0 lbf-in (the 2026 datasheet prints 5.1 ± 1.0 N·m for this part)
Length13.50 ± 0.10 inches (343.0 ± 2.5 mm)
Width6.69 ± 0.08 inches (170.0 ± 2.0 mm)
Height8.54 ± 0.10 inches (216.9 ± 2.5 mm)
Weight75.38 lbs (34.20 kg)
BCI Group Size31 (CSB price list)
Float Charging Voltage13.5 to 13.8 VDC per battery at 25°C (77°F)
Equalization Charging Voltage14.4 to 15.0 VDC per battery at 25°C (77°F)
Operating TemperatureNominal 25°C (77°F); discharge -20°C to 50°C (5°F to 122°F); charge and storage -20°C to 40°C (5°F to 104°F)
Self DischargeLess than 10 percent after 90 days at 25°C; store up to 6 months, or 10 months with an equalization charge, then recharge fully before use
Container MaterialPolypropylene (UL 94-HB); flame retardant 94-V0 available on request, priced as a surcharged option on the CSB price list
StandardsIEC 60896-21/22:2004; UL1973 Listed (MH66728); UL1989 Recognized (MH14533); TUV NORD to ISO 9001:2015
Design LifeUp to 12 years in standby service at 25°C; greater than 12 years on the Eurobat 20°C basis
Warranty4 years (CSB, XTV Taiwan build)
Country of OriginTaiwan
Stock Status at CSBBuild-to-order (non-stock on the CSB price list)

Where This Battery Is Used

  • Macro site and hub cabinets outdoors - 48 volt strings where the load and the hold time have both grown past what the 100 Ah block covers with margin.
  • Remote renewable installations - hybrid power stations that cycle the string on real weather rather than on a test schedule.
  • Substation and switchyard control - outdoor control houses where a group 31 tray is on the drawing and the ambient is the design constraint.

Ordering and Freight

At 75.38 lbs this block ships LTL, palletized, in any quantity, where a residential or limited-access delivery adds $100 for the liftgate and access charge the carrier passes through. A string of four is over 300 lbs and needs a forklift or a pallet jack at the receiving end; tell us if the site has neither. CSB builds this part to order in Taiwan and the lead time is the factory's. Send the string count, the voltage and the receiving arrangements, and a specialist comes back with pricing, lead time and freight in writing in 24 to 48 hours.

Frequently Asked Questions

What does the lowest internal resistance in the range buy me?

Two things. Under load it means less voltage sag for a given current, so the string holds its terminal voltage longer into a discharge, which is where the higher 15 minute power figure comes from. For maintenance it sets the baseline that a conductance or impedance program watches over the years; a block that starts at 3.60 milliohms has further to drift before it crosses the threshold your program treats as end of life. It does not change the discharge ceiling, which stays at 800 amps with the other I2 blocks.

Why is the N·m torque tolerance different on this datasheet?

CSB's 2026 sheet for this part prints 5.1 ± 1.0 N·m where the 12550, 12800 and 121000 sheets print 5.1 ± 0.6. All four give the same 44.9 ± 9.0 lbf-in, and 9.0 lbf-in converts to about 1.0 N·m, so this sheet's metric tolerance is the one that agrees with the imperial figure. Work in lbf-in and the discrepancy disappears. Either way the target is the same and the window is wide enough that a small torque driver set to 45 lbf-in is inside it.

Should the protection study use 2,648 amps?

Yes, and for a series string it is the per-block figure that drives the fault current, because the blocks are in series and share the same current path. A DC fuse or breaker upstream of a 48 volt string of four must be rated to interrupt that current at the string voltage. It is the highest short circuit figure in the XTV range, which is why this block is the one to name explicitly when the study is being written, even if the final selection lands on a smaller size.

What does the XTV range not do?

It is not built for deep cycling and it is not a high rate UPS block. CSB rates it for float service outdoors: sit at 13.5 to 13.8 volts, deliver when the utility drops, recharge, repeat. The discharge tables run out to 20 hours because that is the duty. A load that cycles the string daily belongs on a battery rated in cycles, and a 15 minute UPS transfer belongs on the HR or HRL ranges rated in watts per cell. This block is for the cabinet that has to make it to morning in January, and that is a different job from either.

Same terminal, group 27: CSB XTV121000100 Ah at the 20 hour rate in a shorter case, on the same I2 insert and the same 800 amp ceiling.
Specifying the largest outdoor block?

Give a specialist the load in watts, the hold time, the coldest ambient on record and the tray size. If the calculation needs the 110 Ah figure, this is the block; if it does not, the 100 Ah one saves 9 lbs a block and the difference in freight.

Call 1-877-775-4381  ·  battery specialists, not a call center

WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov (State of California only).

Customer Reviews

Customers Also Viewed