CSB XTV 1272F2 12V 7.2AH AGM High Temperature Battery for Deep Cycle Applications

$26.95
SKU: XTV 1272F2
Availability: Shipping Lead Time is 24 - 48 Hours
Shipping: Free shipping on orders $75 and up
Voltage: 12
Capacity: 7.20 Ah (20-hour rate to 1.75 VPC at 25C, datasheet); 7.2 Ah (CSB price list)
Chemistry: AGM VRLA, pure lead construction
Terminal: F2 Faston tab 0.250 in
Features: Extreme temperature, -20C to 50C discharge, float service outdoors, CSB stock item, 3-year CSB term
Dimensions: 5.94 x 2.55 x 3.88 in (L x W x H)
Design Life: Up to 12 years standby at 25C; Eurobat 20C greater than 12 years
Group Size: M7
CSB XTV 1272F2 12V 7.2AH AGM High Temperature Battery for Deep Cycle Applications

CSB XTV 1272F2 12V 7.2AH AGM High Temperature Battery for Deep Cycle Applications

$26.95
Adding to cart… The item has been added

CSB XTV1272F2 Battery - 12V 7.2Ah Extreme Temperature AGM, F2

The XTV1272F2 is a 12 volt, 7.20 amp hour AGM block rated to discharge from -20°C to 50°C, which is the reason it exists. A standard UPS block from the same factory is rated to -15°C, and five degrees at the cold end is the difference between a roadside cabinet that carries a January outage and one that does not. CSB builds this part for float service outdoors: traffic control, telecom pedestals, remote monitoring, gate and access equipment, anywhere the battery lives in a box that follows the weather. It carries a group M7 footprint on a 0.250 inch F2 Faston tab, weighs 5.66 lbs, and holds 148 watts per battery over 15 minutes to 1.67 volts per cell. It is also one of two XTV parts CSB lists as stock rather than build-to-order, which matters when the cabinet is already dark.

Warranty

Warranty. CSB gives 3 years on the XTV parts built in Vietnam, and this is one of them. Design life is a separate figure: up to 12 years in standby service at 25°C (77°F), and greater than 12 years on the Eurobat 20°C basis. Country of origin is Vietnam. Terms are confirmed in writing with your quote.

Built for the Box Outside

-20°C to 50°C discharge
Five degrees colder at the bottom than CSB's standard UPS blocks, with charge and storage rated -20°C to 40°C.
12 year design life
Up to 12 years in standby service at 25°C, and greater than 12 years on the Eurobat 20°C basis, in a 7.2 Ah case.
Stock item
One of two XTV parts CSB lists as stock rather than build-to-order, alongside the XTV1285F2 in the same case.
  • 7.20 Ah at the 20 hour rate - to 1.75 volts per cell at 25°C, with 6.72 Ah at the 8 hour rate. The XTV badge is the 20 hour capacity itself, not a watt figure.
  • 148 watts per battery at 15 minutes - to 1.67 volts per cell, from the CSB series discharge tables. The per-part datasheet starts its power table at 30 minutes.
  • 130 amps maximum discharge for 5 seconds - with 305 amps of short circuit current and an internal resistance of approximately 20.40 milliohms.
  • 2.16 amps maximum charge current - a recharge ceiling sized for a small float charger, which is what most of these cabinets carry.
  • Less than 10 percent self-discharge over 90 days - storable for 6 months at 25°C, or 10 months with an equalization charge, before a full recharge is required.

Technical Specifications

CSB XTV1272F2 Specifications
Part NumberXTV1272F2 (also written XTV 1272F2, XTV1272 F2, XTV-1272F2 and xtv1272f2)
SeriesXTV, Extreme Temperature, 12 volt top terminal
Battery TypeAGM, valve regulated lead acid (VRLA), pure lead construction
Nominal Voltage12V
Capacity, 20 Hour Rate7.20 Ah to 1.75 VPC at 25°C (CSB price list lists 7.2 Ah)
Capacity, 8 Hour Rate6.72 Ah to 1.75 VPC; 6.56 Ah to 1.80 VPC
Watts Per Battery, 15 Minutes148 W to 1.67 VPC at 25°C (CSB XTV series tables, RA240531)
Discharge Current, 60 Minutes4.47 A to 1.67 VPC at 25°C
Discharge Current, 5 Hours1.24 A to 1.67 VPC at 25°C
Maximum Charge Current2.16 A
Maximum Discharge Current130 A for 5 seconds
Short Circuit Current305 A for 5 seconds
Internal ResistanceApproximately 20.40 milliohms
Terminal TypeF2 Faston tab, 0.250 inch
Length5.94 ± 0.08 inches (150.9 ± 2.0 mm)
Width2.55 ± 0.04 inches (64.8 ± 1.0 mm)
Height3.88 ± 0.04 inches (98.6 ± 1.0 mm)
Weight5.66 lbs (2.57 kg)
BCI Group SizeM7 (CSB price list)
Float Charging Voltage13.5 to 13.8 VDC per battery at 25°C (77°F)
Equalization Charging Voltage14.4 to 15.0 VDC per battery at 25°C (77°F)
Operating TemperatureNominal 25°C (77°F); discharge -20°C to 50°C (5°F to 122°F); charge and storage -20°C to 40°C (5°F to 104°F)
Self DischargeLess than 10 percent after 90 days at 25°C; store up to 6 months, or 10 months with an equalization charge, then recharge fully before use
Container MaterialABS (UL 94-HB); flame retardant 94-V0 available on request, priced as a surcharged option on the CSB price list
StandardsIEC 60896-21/22:2004; UL1973 Listed (MH66728); UL1989 Recognized (MH14533); TUV NORD to ISO 9001:2015
Design LifeUp to 12 years in standby service at 25°C; greater than 12 years on the Eurobat 20°C basis
Warranty3 years (CSB, XTV Vietnam build)
Country of OriginVietnam
Stock Status at CSBStock item (CSB price list); most of the XTV range is build-to-order

Where This Battery Is Used

  • Traffic signal and intersection cabinets - battery backup units that sit in a roadside enclosure and see the full outdoor swing every year.
  • Telecom pedestals and small outdoor nodes - the 7 Ah class of block that backs a fiber node or a small cell radio through a short outage.
  • Gate operators, access control and remote sensors - unheated equipment where a standard indoor UPS block is being asked to do a job it was not rated for.

Ordering and Freight

At 5.66 lbs this block ships by parcel carrier in any quantity a cabinet program needs, and a pallet of them moves LTL, where a residential or limited-access delivery adds $100 for the liftgate and access charge the carrier passes through. Because CSB lists this part as stock, lead time runs shorter than the rest of the XTV range. Send the quantity, the ZIP and the date it has to land, and a specialist comes back with pricing, lead time and freight in writing in 24 to 48 hours.

Frequently Asked Questions

What does the extreme temperature rating change about the battery?

The discharge envelope. CSB rates this block to deliver from -20°C to 50°C where its standard UPS and HRL ranges are rated from -15°C. The plates, the electrolyte fill and the case are all the same AGM construction, so it charges on the same 13.5 to 13.8 volt float window and behaves like any other CSB block indoors. What you are paying for is the guarantee that it will still deliver its rated current at the bottom of a cold night, which a block rated to -15°C does not promise.

Is 7.20 Ah the same as the 7.2 on the label?

Yes. The XTV range is badged by its 20 hour capacity, so the part number and the datasheet agree to the decimal on this block. That is unlike CSB's HR and HRL ranges, which are badged by watts per cell and can sit either side of the measured figure. If you are replacing a 7.2 Ah block from another maker, compare the 20 hour rating at 1.75 volts per cell on both sheets, because some manufacturers quote the 10 hour or 5 hour figure and the number looks smaller than it is.

Can it be charged in the cold?

Down to -20°C, and the charge and storage limit at the top is 40°C rather than the 50°C discharge ceiling. Lead acid chemistry accepts charge slowly when it is cold, so a cabinet that spends the winter near the bottom of the range will recover from an outage more slowly than the datasheet's room temperature curves suggest. A temperature compensated charger helps here; the datasheet does not publish a compensation coefficient for this part, so the charger's own setting applies.

Why choose this over the XTV1285F2 in the same case?

Cost and availability, when 7.2 Ah covers the load. The two share a case, a terminal and a weight within two tenths of a pound, and both are stock items at CSB. The 1285 carries about 22 percent more capacity and about 24 percent more 15 minute power for the same footprint. If the drawing calls for 7.2 Ah, this is the exact match. If the runtime calculation is tight, the 1285 buys margin without changing the cabinet layout.

Same case, more capacity: CSB XTV1285F28.80 Ah at the 20 hour rate and 183 watts per battery at 15 minutes, on the same M7 footprint and F2 tab.
Sizing a cabinet program?

Tell a specialist how many cabinets, what the coldest site sees in January and how long the backup has to carry. The XTV range separates from the standard blocks on the low temperature figure. Size against that number.

Call 1-877-775-4381  ·  battery specialists, not a call center

WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov (State of California only).

Customer Reviews

Customers Also Viewed