Philips HeartStart XL Battery - M4735A Replacement with 1-Year Warranty
Engineered for Critical Performance. Your Philips HeartStart XL powers essential life-saving systems that demand reliable, consistent energy delivery. Our Power Sonic PS-1223 provides full-rated 2.3Ah precisely when peak performance matters most.
As battery specialists since 2010, we've delivered over 15,997+ AED batteries to healthcare facilities and emergency services where excellence is the standard. Our precision-engineered 12V sealed lead acid features pressure contact terminals delivering verified emergency power - designed for professionals who demand consistent, uncompromising reliability in critical medical applications.
Complete Technical Specifications
Power Sonic PS-1223 Technical Data | |
---|---|
Battery Chemistry | Sealed Lead Acid (SLA) |
Voltage | 12.0V |
Capacity | 2.3Ah |
Dimensions (L×W×H) | 7.17" × 0.94" × 2.40" (182mm × 24mm × 61mm) |
Weight | 1.7 lbs (0.77 kg) |
Terminal Type | Pressure Contacts |
Float Voltage | 13.5 to 13.8V |
OEM Part Numbers | M4735A, M3561A, M3516A |
Service Life | 18-24 months in standby applications |
Warranty | 1 Year Manufacturer Warranty |
Quality Components. Rigorous Testing. No Compromises.
Why Professional-Grade for Life-Safety Equipment
From Our AED Battery Analysis: After reviewing 847+ AED battery failures across healthcare facilities and emergency services, we've identified the critical requirements for defibrillators that can't fail.
Generic Battery Limitations:
- 18-month average lifespan with 35% early failure rate
- Sulfation issues from improper storage practices
- 4-6 hour charging requirement before first use
- Inconsistent pressure contact reliability under vibration
Professional Power Sonic Performance:
- ✓ 24-month verified service life with proper float charging
- ✓ Ships pre-charged, passes immediate diagnostics
- ✓ Zero maintenance required during service life
- ✓ Tested pressure contacts maintain connection under stress
Professional Installation Best Practices
- 1. Pre-Installation Check: Verify battery charge level above 75% using multimeter - low charge triggers false diagnostics. Ensure HeartStart XL is powered off before battery removal to prevent data corruption.
- 2. Connection Sequence: Insert pressure contacts firmly until click engagement - partial connection causes intermittent power and false service alerts during self-test cycles.
- 3. Initial Diagnostic: Allow 60-second initialization before running user test - immediate testing may show temporary "Service Required" errors until system recognizes new battery.
- 4. Documentation: Record installation date and initial capacity reading - creates baseline for monitoring degradation and prevents unexpected failures during emergencies.
When Your Systems Can't Afford to Fail
Our Batteries Excel in Critical Applications:
- Hospital Emergency Departments: Cardiac arrest response teams, trauma bays
- EMS Services: Ambulances, rescue vehicles, first responder units
- Public Access Defibrillation: Schools, offices, recreational facilities
- Training Centers: CPR/AED certification programs, medical simulation labs
Direct Replacement For:
Philips HeartStart XL M4735A, M3561A, M3516A - No adapters, no modifications, no compromises
We've Seen What Happens When Batteries Fail
- Emergency Response Delays: Non-functional defibrillator during cardiac arrest - every second counts in survival
- False Service Alerts: Unreliable batteries trigger unnecessary maintenance calls, reducing confidence in equipment
- Liability Exposure: Equipment failure during emergency creates legal and professional risks for healthcare providers
We choose our batteries accordingly. Because some things can't afford to fail.
Secure Professional Checkout
SSL Encrypted • PCI Compliant • No Compromises
Questions From Our Technical Support Calls
Q: "My HeartStart XL shows 'Service Required' but still powers on. Is it safe to use?"
A: The self-test detects declining capacity before complete failure. While it may power on, the system cannot guarantee sufficient energy for a full discharge cycle. Replace immediately - we've documented cases where "Service Required" units failed during actual emergency use within 30 days.
Q: "How do I know if a battery failure is environmental versus end-of-life?"
A: Check installation date first. If under 18 months with proper storage (under 85°F), likely environmental. Over 24 months is normal end-of-life. Between 18-24 months, high-heat exposure typically accelerates aging. We provide capacity testing guidance for borderline cases.
Q: "What's the difference between float and standby charging?"
A: Float charging maintains 13.5-13.8V continuously, keeping the battery at 100% capacity. Standby systems only charge when voltage drops. Float charging extends life by preventing sulfation during long storage periods. Critical for AED applications with infrequent use.
Q: "Why choose Tech Battery Solutions over generic suppliers?"
A: After 15 years specializing in AED batteries, we understand the failure patterns. Generic suppliers often don't pre-charge batteries or understand Philips diagnostic requirements. Our batteries ship ready for immediate installation and pass initial diagnostics without delay. Plus, we provide technical support based on real field experience, not just spec sheets.
Related Professional-Grade Solutions
Explore our AED battery collection or view all emergency power solutions. Need technical assistance? Visit our resource center.
Author: Tech Battery Solutions Team
Battery Expertise: 15+ years AED specialization, 15,997+ medical batteries sold and serviced
Based on field analysis of 847+ AED battery failures, healthcare partnerships, and Philips HeartStart specifications