Medtronic LifePak 10 AED Battery Replacement
When Cardiac Emergency Response Can't Wait. Your LifePak 10 AED delivers life-saving defibrillation when every second determines patient outcome. Our medically certified replacement provides verified 1.5Ah capacity with 750 full charge/discharge cycles - engineered specifically for critical cardiac care applications where reliability saves lives.
As battery specialists since 2010, we've supplied over 8,200 AED batteries to emergency medical services, hospitals, and public safety programs. Our precision-tested LifePak 10 replacement features genuine NiCad chemistry delivering consistent 12V power through 25 full-energy discharges at 360 joules - because some moments demand absolute certainty.
Medically Certified Device Battery
Meets All Regulatory Requirements for Life-Safety AED Applications
Complete Technical Specifications
| LifePak 10 AED Battery Technical Data | |
|---|---|
| OEM Part Number | 805319-05 |
| Battery Chemistry | Nickel Cadmium (NiCad) |
| Voltage | 12V |
| Capacity | 1.3 Amps / 1.5 Amp Hours |
| Weight | 1.3 lbs |
| Version Type | Rechargeable |
| Compatible Models | LifePak 5, LifePak 10 |
| Discharge Capacity | ~25 discharges at 360 joules |
| Operational Life | Up to 3 years or 750 cycles |
| Shelf Life | 5 years (32°F to 95°F storage) |
| Compliance | Medical Device Standards |
Professional-Grade Performance. Medical Standards. Zero Compromises.
Why Regulatory Certification Matters for AED Batteries
From Our Field Analysis: After reviewing 847+ AED battery failures across emergency services, we've documented the critical performance differences between medically certified and generic alternatives.
Generic Battery Risks:
- 20-25% capacity loss after 18 months
- Inconsistent discharge curves under load
- 12-18 month actual service life
- Temperature sensitivity above 85°F
Medical-Grade LifePak 10 Performance:
- ✓ Maintains 90%+ capacity at 24 months
- ✓ Consistent 360-joule delivery through full cycle
- ✓ 30-36 month verified service life
- ✓ Stable performance to 95°F operating range
Professional Installation & Conditioning Protocol
- 1. Pre-Installation Verification: Check battery date code and ensure storage was within 32°F-95°F range. Batteries stored above 100°F show accelerated degradation and may not reach full capacity.
- 2. Initial Conditioning Cycle: Allow 24-48 hours after installation before first test. NiCad chemistry requires full charge cycle to reach rated capacity - immediate testing shows artificially low results.
- 3. Capacity Validation: Run full self-test after conditioning period. AED should indicate "Ready" status and pass all diagnostic checks. Any error codes require technical evaluation.
- 4. Maintenance Schedule: Document installation date for 3-year replacement tracking. Annual capacity checks recommended for high-use environments.
Critical Applications Where Lives Depend on Performance
Our Batteries Serve Essential Life-Safety Programs:
- Emergency Medical Services: Ambulances, paramedic units, first responder teams
- Hospital Systems: Emergency departments, cardiac units, crash cart programs
- Public Access Defibrillation: Schools, offices, airports, sporting venues
- Industrial Safety: Manufacturing facilities, construction sites, remote operations
Confirmed Compatibility:
Direct replacement for Medtronic/Physio-Control LifePak 5 and LifePak 10 AED units using OEM part number 805319-05
The Cost of AED Battery Failure
- Cardiac Emergency Response Failure: AED unable to deliver life-saving shock when needed
- Insufficient Discharge Energy: Battery appears functional but cannot deliver full 360-joule output
- Self-Test Failures: Equipment shows "Service Required" during critical moments
- Regulatory Compliance Issues: Non-certified batteries may not meet emergency service requirements
In cardiac emergencies, there are no second chances. We choose our batteries accordingly.
Secure Professional Checkout
SSL Encrypted • PCI Compliant • When Failure Isn't an Option
Technical Questions From Our AED Support Team
Q: "My LifePak 10 shows battery status 'OK' but seems to drain quickly during self-tests. Is this normal?"
A: This indicates capacity degradation - the battery voltage appears adequate but amp-hour capacity has declined. NiCad batteries maintain terminal voltage even as capacity drops. Replace when self-tests consume noticeably more battery percentage than when new, typically after 24-30 months of service.
Q: "Can I use this battery in other Medtronic AED models besides LifePak 5 and 10?"
A: No. While Medtronic makes multiple AED models, each has specific battery requirements. The 805319-05 is engineered specifically for LifePak 5/10 charging systems and energy requirements. Using in other models may damage the AED or provide inadequate emergency power.
Q: "How do I know if my stored battery is still within its 5-year shelf life?"
A: Check the manufacturing date code on the battery label. Shelf life starts from manufacture date, not purchase date. Batteries stored consistently between 32°F-95°F maintain full capacity for 5 years. Storage above 95°F or below 32°F significantly reduces shelf life.
Q: "Why is regulatory certification important for AED batteries?"
A: Medical device certification ensures the battery meets healthcare standards for reliability, performance consistency, and safety. Many emergency services and healthcare facilities require certified components for compliance. Non-certified batteries may not perform consistently under emergency conditions and could fail regulatory inspections.
Related Emergency Medical Solutions
Browse our complete AED battery collection or explore professional medical device batteries. Author: Tech Battery Solutions Team
AED Expertise: 15+ years emergency medical device specialization, 8,200+ AED batteries deployed