Voltage: 12
Capacity: 145 Ah (10-hour rate to 1.80 VPC at 25C); 620 W per cell (15-min to 1.67 VPC)
Chemistry: Pure lead thin plate AGM VRLA
Terminal: M6 threaded insert (T8); M8 (T11) optional
Dimensions: 13.4 x 6.69 x 10.9 in (L x W x total H); 340.9 x 170 x 275.7 mm
Design Life: 15 years at 25C on float (Leoch)
Features: Pure lead thin plate, 3,190 A short circuit, -40C to 65C discharge, 24-month shelf life at 25C, PC-ABS UL 94 V-0 case, 60-month Leoch term
Group Size: Not published by Leoch; 340.9 x 170 mm PLX case shared with PLX12-500 and PLX12-540
Leoch PLX12-620 Pure Lead High Rate Battery

Leoch PLX12-620 Pure Lead High Rate Battery

$531.95
Adding to cart… The item has been added

Leoch PLX12-620 Battery - 12V 145Ah Pure Lead High Rate AGM, M6

The PLX12-620 is the largest top-terminal block in Leoch's pure lead PLX range: 620 watts per cell over 15 minutes to 1.67 volts per cell, 145 Ah at the 10-hour rate, in a 340.9 by 170 mm case that stands 275.7 mm with terminals and weighs 44 kg (97.0 lbs). It shares that case with the PLX12-500 and PLX12-540, so a string built on one of them can be re-rated upward without changing the tray. The thin pure lead plates are what make the 15-minute number possible: low internal resistance (about 3.5 milliohms), a short-circuit current of 3,190 amps, and a design life Leoch rates at 15 years at 25°C on float. It is a UPS battery first, sized for the first quarter hour of an outage rather than for hours of trickle, and it is quoted with a minimum order of four units.

Warranty

Warranty. Leoch warrants the PLX line for 60 months, full replacement. Design life is a separate figure and is not the warranty: 15 years at 25°C (77°F) on float service, from the PLX12-620 datasheet. Terms are confirmed in writing with your quote.

What the Pure Lead Plate Buys You

620 watts per cell at 15 minutes
3,720 watts from one 12 volt block over the window a UPS is sized on, to 1.67 volts per cell. The 5-minute figure is 1,001.8 watts per cell.
One case, three ratings
The 340.9 by 170 by 275.7 mm case is shared with the PLX12-500 and PLX12-540. Same tray, same terminal pitch, more watts at the top of the range.
24 months on the shelf
Leoch allows up to 24 months of storage at 25°C before a freshening charge, which suits spares held for a string that will not be replaced all at once.
  • 145 Ah at the 10-hour rate - to 1.80 volts per cell at 25°C, which is the figure to size a long-duration runtime on. Older listings rounded this part to 150 Ah; the current sheet says 145.
  • 560.2 amps for 5 minutes - to 1.67 volts per cell, and 338.6 amps for 15 minutes, the two rows that describe a large UPS riding through a transfer and a short outage.
  • 121.4 amps for one hour - to 1.67 volts per cell, for the site that needs an hour of bridge before a generator carries the load.
  • 3,190 amps short-circuit current - with an internal resistance of approximately 3.5 milliohms fully charged, the numbers that set breaker coordination on the DC side.
  • -40°C to 65°C discharge window - charge from -20°C to 54°C, in a PC-ABS case rated UL 94 V-0, heat sealed and 100 percent leak tested.

Technical Specifications

Leoch PLX12-620 Specifications
Part NumberPLX12-620 (also written PLX12 620, PLX 12-620 and plx12-620)
SeriesLeoch PLX, pure lead thin plate high rate, top terminal
Battery TypePure lead thin plate AGM, valve regulated lead acid (VRLA)
Nominal Voltage12V (6 cells)
Nominal Rating, 15 Minutes620 W per cell to 1.67 VPC at 25°C (3,720 W per battery)
Capacity, 10-Hour Rate145 Ah to 1.80 VPC at 25°C
Discharge Current, 5 Minutes560.2 A to 1.67 VPC; 410.6 A to 1.80 VPC
Discharge Current, 15 Minutes338.6 A to 1.67 VPC; 280.2 A to 1.80 VPC
Discharge Current, 1 Hour121.4 A to 1.67 VPC; 110.4 A to 1.80 VPC
Discharge Power, 1 Hour227.3 W per cell to 1.67 VPC
Short Circuit Current3,190 A
Internal ResistanceApproximately 3.5 milliohms, fully charged, at 25°C
Maximum Charge Current0.3C (43.5 A) at 25°C
Float Charge Voltage2.27 ± 0.02 V per cell at 25°C (13.62 V per battery nominal)
Equalization Charge Voltage2.35 to 2.40 V per cell at 25°C
Temperature Coefficient-3 mV per cell per °C on float; -4 mV per cell per °C on equalize
Terminal TypeM6 threaded insert (T8); M8 (T11) optional
Length340.9 mm (13.4 inches)
Width170 mm (6.69 inches)
Container Height273.2 mm (10.8 inches)
Total Height275.7 mm (10.9 inches)
Weight44 kg (97.0 lbs)
Operating TemperatureDischarge -40°C to 65°C (-40°F to 149°F); charge -20°C to 54°C (-4°F to 129°F); storage -20°C to 50°C (-4°F to 122°F)
Self Discharge and StorageUp to 24 months storage at 25°C; freshening charge when open circuit voltage approaches 2.10 V per cell or at the storage limit
Container MaterialPC-ABS, flame retardant to UL 94 V-0
StandardsIEC 60896; Eurobat "Very Long Life" classification; CE and UL; built in IATF 16949, ISO 9001, ISO 14001 and ISO 45001 certified plants
Design Life15 years at 25°C on float service (Leoch)
Warranty60 months, full replacement (Leoch, PLX)

Where This Battery Is Used

  • Three-phase UPS strings - the data center and hospital systems where the runtime target is 10 to 15 minutes at full load and the string is sized on watts per cell, not amp hours.
  • High power DC backup - switchgear tripping supplies, testing laboratories and control rooms that pull a large current for a short time and then sit on float for years.
  • Engine start and emergency power - starting systems and emergency supplies where the 560 amp five-minute figure does the work once or twice a year.

Ordering and Freight

Minimum order is four units. At 97 lbs each a set ships strapped to a pallet by LTL freight, never by parcel, and a residential or limited-access delivery adds $100 for the liftgate and access charge the carrier passes through. Send the quantity, your delivery ZIP and your requested-by date. A specialist confirms availability, lead time, volume pricing and freight in writing in 24 to 48 hours.

Frequently Asked Questions

The page says 15 years and 60 months. Which one is the warranty?

The 60 months. Leoch warrants PLX batteries for 60 months with full replacement; no other warranty figure appears on this page. The 15 years is Leoch's design life, an engineering estimate of service under float conditions at 25°C, and it is published on the datasheet as a separate figure. A battery that reaches its design life has done what the engineers modeled; a battery that fails inside 60 months is a warranty matter. The two numbers describe different things and this page keeps them apart on purpose. Terms are confirmed in writing with your quote.

Is the PLX12-620 a 145 Ah or a 150 Ah battery?

145 Ah. The current Leoch datasheet (LB-PLX12-620-PD-EN-V5.3, October 2025) rates it at 145 Ah over 10 hours to 1.80 volts per cell at 25°C, and the 20-hour row of the discharge table gives 7.31 amps, which works out to 146 Ah. Older listings, including the previous version of this page, rounded the part to 150 Ah. If a runtime calculation was done on 150, rerun it on 145; the difference is about 3 percent and only matters on a string sized with no margin. For a UPS the number that sizes the string is the 620 watts per cell at 15 minutes, which has not changed.

How does the PLX12-620 differ from the PLX12-620FT(A)?

Same 620 watt rating, different battery. The PLX12-620 on this page is a top-terminal block, 340.9 by 170 mm and 275.7 mm tall, rated 145 Ah. The PLX12-620FT(A) is Leoch's front-terminal version for 23-inch telecom racks: 559 by 125 mm, 277 mm tall, 150 Ah, 48.5 kg, with the terminals on the front face so a string can be serviced without pulling the tray. If the cabinet was built for one, the other will not drop in. Check the terminal position and the footprint before quoting a swap, and send a photo of the existing block if there is any doubt.

What terminal hardware ships with it?

The standard terminal is an M6 threaded brass insert, Leoch's T8 pattern, and the sheet lists M8 (the T11 pattern) as an optional build. Leoch's range summary also lists a T6 to M6/M8 adaptor for front-terminal parts, and the inter-cell connectors on an existing string set which one you want. Specify the terminal when you request the quote; a string with M8 hardware fed by an M6 battery means new connectors or adaptors, and the quote will call that out rather than leave it to the installer.

One step down in the same case: Leoch PLX12-540540 watts per cell at 15 minutes and 135 Ah, 43.5 kg, in the identical 340.9 by 170 by 275.7 mm footprint.
Re-rating a UPS string on the PLX12-620?

Send the quantity, the UPS model or the current battery part number, and your delivery ZIP. A specialist confirms the terminal, the footprint and the lead time, and quotes the full set in writing.

Call 1-877-775-4381  ·  battery specialists, not a call center

WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov (State of California only).

Customer Reviews

Customers Also Viewed