CSB HR1227W 12V 6.5Ah F2 Terminal High-Rate AGM Battery

$25.95
SKU: HR1227W
Availability: Request Quote For Availability
Shipping: Free shipping on orders $75 and up
Voltage: 12
Capacity: 6.5 AH
Chemistry: AGM
Terminal: F2
Features: High-Rate Series
CSB HR1227W 12V 6.5Ah F2 Terminal High-Rate AGM Battery
CSB HR1227W 12V 6.5Ah F2 Terminal High-Rate AGM Battery
$25.95
Adding to cart… The item has been added

CSB HR1227W F2 Battery - 12V High Rate VRLA, 27 Watts Per Cell at 15 Minutes

The HR1227W F2 packs 27.0 watts per cell over the 15-minute window into the small 3.54 by 2.76 by 4.18 inch case, the stronger of the two CSB high-rate models built on this footprint. It runs the F2 Faston tab, weighs 4.34 lbs, and holds a 130 A maximum discharge rating. Where a compact UPS asks its battery for a hard sprint, this is the plate set CSB built for it.

Warranty

Warranty. CSB's manufacturer term on the HR line is 1 year. Design life is a separate figure: up to 5 years in standby service at 77°F. Terms are confirmed in writing with your quote.

The Strong Small Brick

27.0 W per cell, 15 minutes
162 watts per battery for 15 minutes to 1.67 volts per cell.
130 A maximum discharge
The HR1221W in the same case is rated 90 A.
19.9 milliohms internal resistance
Lower than the 23.0 milliohms of the HR1221W in the same case.
  • Sealed VRLA-AGM construction - recombination rated up to 99% by CSB, no maintenance.
  • IEC 61056-1/2:2012 built, UL1973 Listed (MH66728), UL1989 Recognized (MH14533) - the file numbers printed on the CSB datasheet linked below.
  • Wide discharge window - rated for discharge from -15°C up to +50°C when the install is less than ideal.

Technical Specifications

CSB HR1227W F2 Specifications
Part NumberHR1227W F2 (also searched as HR1227WF2, HR 1227W F2, CSB HR1227W)
Battery TypeVRLA-AGM, high rate, top terminal
Nominal Voltage12V
Power Rating, 15-minute27.0 watts per cell to 1.67 VPC at 77°F (162 W per battery)
Power Rating, 5-minute53.0 watts per cell to 1.67 VPC
Max Discharge Current130 A (F2 build; the F1 build is rated 100 A)
Short Circuit Current424 A
Internal ResistanceApprox. 19.9 milliohms
Terminal TypeF2 Faston tab, 0.250 inch
Length3.54 inches (90.0 mm)
Width2.76 inches (70.0 mm)
Height4.18 inches (106.1 mm)
Weight4.34 lbs (1.97 kg)
ContainerABS (UL 94-HB); flame-retardant 94-V0 build available on request
Operating TemperatureDischarge -15°C to +50°C; charge and storage -15°C to +40°C
Float Charging Voltage13.5 to 13.8 Vdc per battery at 77°F
Country of OriginVietnam
Design LifeUp to 5 years standby at 77°F (CSB)
Warranty1 year (CSB)
Technical Documentation

Where This Battery Is Used

  • Compact UPS units carrying real load - the small-case models that protect network gear rather than a single desktop.
  • Telecom and security equipment holdover - short-window power where cabinet space is fixed.

Ordering and Shipping

These are parcel-weight units at 4.34 lbs; volume orders palletize as LTL freight. Send the quantity, your delivery ZIP and your requested-by date, and a specialist returns a written quote with volume pricing in 24 to 48 hours.

Frequently Asked Questions

Why does a small UPS need a high-rate battery at all?

Because of how the rating is earned. A battery rated for 20-hour discharges delivers a shrinking fraction of its energy as the draw gets faster, and a UPS empties its battery in minutes. The HR series is rated in watts per cell over 15 minutes, the window a UPS runs. In this case size, that is the difference between the runtime you calculated and the runtime you get.

My old battery has narrower terminal tabs. Is that a problem?

The narrow tab is the F1; this listing carries the 0.250-inch F2. The two do not mate without an adapter, and an adapter adds a resistance point right where the current is highest. CSB builds this model in an F1 version, rated 100 A maximum discharge, and we quote it on request. Match what your connector takes and say which tab you need on the quote.

Can the HR1227W live in a hot closet?

It is rated to discharge at ambient temperatures up to 122°F, so it will do its job in the heat. Living there is a different matter: every VRLA battery ages faster above 77°F, and the design life figure assumes that cooler number. If the closet runs hot year round, plan a shorter replacement cycle or move air through the space, whichever costs the site less.

How long can a spare HR1227W sit on the shelf?

The CSB datasheet gives up to 6 months at 77°F, with self-discharge under 10% over the first 90 days. Warmer storage shortens that window, so shelve spares somewhere cool and recharge them inside it.

The same case in the HR1221W F2The CSB HR1221W F2 delivers 25.0 watts per cell from this footprint.
Get the HR1227W F2 priced for your site

Send the quantity, your delivery ZIP and your requested-by date. A specialist confirms the terminal build, availability, the warranty term and shipping in writing, with no obligation to buy.

Call 1-877-775-4381  ·  battery specialists, not a call center

WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov (State of California only).