C&D BBG-220RT Broadband GEL Battery

$489.95
SKU: BBG-220RT
Availability: Request Quote For Availability
Shipping: Free shipping on orders $75 and up
Voltage: 12
Chemistry: Gel VRLA, gelled electrolyte, polyethylene separators
Features: Broadband
Terminal: 1/4-20 UNC bolt, 110 in-lbs (12.4 N-m)
Minimum Order Quantity: 4 Batteries
Capacity: 220 minutes at a 25 A constant current load to 1.75 VPC at 25C; 67.70 A for 1 hour, 12.60 A for 8 hours
Dimensions: 13.42 x 6.80 x 8.48 in
C&D BBG-220RT Broadband GEL Battery

C&D BBG-220RT Broadband GEL Battery

$489.95
Adding to cart… The item has been added

C&D BBG-220RT Battery - 12V 220 Minute Broadband Gel VRLA

Gel is the chemistry C&D points at the hard locations, and the BBG-220RT is the longest-running block in its Broadband gel line, rated 220 minutes at a 25 amp constant current load to 1.75 volts per cell at 77°F. C&D's own latitude map puts the BBG series in Zone 1 at 40 degrees and above and in Zone 4 at 30 degrees and below, where an outdoor enclosure bakes in August and freezes in February. The gelled electrolyte carries heat away by thermal mass and not by airflow, so a sealed pedestal with no ventilation still gets some cooling path. The block is 13.42 by 6.80 by 8.48 inches and 73 lbs, with a discharge table running from 67.70 amps for one hour to 1.20 amps for a hundred.

Warranty

Warranty. C&D's term on the Broadband gel series is 2 years, under C&D's Broadband series limited warranty. Design life is a separate figure: C&D publishes no design life for the gel series and states a 5+ year service life. Terms are confirmed in writing with your quote.

Built for the Enclosure That Swings

220 minutes, the top gel rating
At a 25 amp constant current load to 1.75 volts per cell at 77°F, the highest runtime C&D publishes for the BBG series.
5.5 amps for twenty hours
16.10 amps for six hours, 10.20 for ten, 2.40 for forty-eight, on the same table and the same end point.
2,600 amps short circuit
The highest figure in the gel group, alongside an 800 amp maximum discharge current that holds across the broadband range.
  • Gel chemistry for temperature extremes - C&D's own zone map places the BBG line at 40 degrees latitude and above and at 30 degrees and below, and leaves the middle zones open to either technology.
  • Float band 13.5 to 13.8 VDC per unit - average at 77°F (25°C), the setting a cable power supply's charger holds between outages.
  • Inter unit connectors and racks - both listed as available accessories for the Broadband series, which matters when a pedestal retrofit changes the block spacing.
  • Nominal operating window of +74°F to +80°F - C&D's stated normal range for the series, and the band an enclosure's ventilation should be aiming at.
  • Polyethylene separators - unlike an AGM mat, they hold float current down as the cabinet warms, which is where a gel block earns its place in an uncontrolled location.

Technical Specifications

C&D BBG-220RT Specifications
Part NumberBBG-220RT (also searched as bbg 220 rt, BBG220RT and 220RT; C&D Broadband gel series)
SeriesBroadband BBG, gelled VRLA design
Battery TypeGel VRLA, gelled electrolyte with polyethylene separators
Nominal Voltage12V (6 cells per unit)
Runtime Rating220 minutes at a 25 A constant current load to 1.75 VPC at 77°F (25°C)
Constant Current to 1.75 VPC67.70 A for 1 hr, 40.40 for 2 hr, 29.10 for 3 hr, 22.90 for 4 hr, 16.10 for 6 hr, 12.60 for 8 hr, 10.20 for 10 hr, 8.70 for 12 hr, 5.50 for 20 hr, 4.60 for 24 hr, 2.40 for 48 hr, 1.60 for 72 hr, 1.20 for 100 hr (all at 77°F)
Ampere-Hour RatingNo published figure; C&D rates the Broadband series in runtime minutes and constant current amperes
Maximum Discharge Current800 A
Short Circuit Current2,600 A
Terminal Type1/4-20 UNC bolt
Terminal Torque110 in-lbs (12.4 N-m)
Length13.42 inches (341 mm)
Width6.80 inches (173 mm)
Height8.48 inches (215 mm)
Weight73 lbs (33 kg)
Float Charging Voltage13.5 to 13.8 VDC per unit average at 77°F (25°C)
Recommended Maximum Charging CurrentC20/5 amperes (23.12 A)
Maximum AC Ripple0.5% RMS or 1.5% P-P of float charge voltage recommended; 1.4% RMS (4% P-P) allowed; 4.6 A RMS current allowed (C20/20)
Operating TemperatureDischarge -40°F to +160°F (-40°C to +71°C); charge -10°F to +140°F (-23°C to +60°C) with temperature compensation
Nominal Operating Temperature+74°F to +80°F (23°C to 27°C)
Self Discharge18 months at 77°F (25°C), then a freshening charge is required
AccessoriesInter unit connectors and racks available
Design LifeNo published design life; C&D states a 5+ year service life for the BBG gel series
Warranty2 years (C&D Broadband series limited warranty, gelled VRLA design)
Minimum Order4 units

Where This Battery Is Used

  • Northern and southern CATV plant - the latitude bands where C&D specifies gel over AGM for the enclosure temperature alone.
  • Long-carriage standby supplies - nodes and amplifier cascades held up for the longest runtime the gel line offers.
  • Security and industrial UPS cabinets - two further markets C&D lists for the Broadband series, on the same float and the same terminal hardware.

Ordering and Freight

Minimum order is 4 units. At 73 lbs per block a set ships freight pre-paid by LTL to a commercial address; a residential or limited-access delivery adds $100, which is the liftgate and access charge the carrier bills us. Send the quantity, your delivery ZIP and your requested-by date, and a specialist returns a written quote with volume pricing in 24 to 48 hours.

Frequently Asked Questions

Does the 220 in BBG-220RT mean 220 amp hours?

No. It is 220 minutes at a 25 amp constant current load, measured to 1.75 volts per cell at 77°F. C&D names every block in the Broadband range by that runtime figure and publishes no ampere-hour rating for the series at all. A sizing worksheet written around amp-hours needs the constant current table instead: 67.70 amps for one hour, 12.60 for eight, 5.50 for twenty.

How long will a BBG-220RT run a 16 amp load?

Six hours to 1.75 volts per cell at 77°F, with 16.10 amps sitting on that column. Drop the load to 12.60 amps and the block runs eight hours; raise it to 22.90 and it runs four. A 36 volt supply built from three blocks pulling 16 amps therefore holds about 580 watts for six hours at room temperature. Enclosure temperature moves all of it, so quote the site ambient alongside the load.

Where does the BBG-220RT sit against the BBA-240PLP?

Twenty minutes of runtime apart and a different chemistry underneath. The 240PLP is a pure lead AGM at 240 minutes and 75 lbs; the 220RT is gel at 220 minutes and 73 lbs, on the identical 13.42 by 6.80 by 8.48 inch case. C&D's guidance is geographic rather than numeric: gel in the hottest and coldest zones, either technology between 30 and 39 degrees latitude, where the AGM's longer service life and higher runtime come into play.

Does a BBG-220RT need a freshening charge before it goes into service?

It depends how long it has been sitting. C&D rates a stored gel block for 18 months at 77°F before a freshening charge is required, and the interval shortens as storage temperature rises. Check the date code against that window before a block goes on the strand, because a partially self-discharged cell put straight onto float in a hot pedestal starts its service behind. Ask for the date code with your quote.

Shorter case, lower runtime: C&D BBG-180RT180 minutes at 25 amps in a 12.50 by 6.83 by 8.05 inch jar at 63 lbs, for pedestals that will not clear 8.48 inches.
Get the BBG-220RT priced for your plant

Send the quantity, your delivery ZIP and your requested-by date. A specialist confirms availability, the warranty term, volume pricing and freight in writing, with no obligation to buy.

Call 1-877-775-4381  ·  battery specialists, not a call center