Voltage: 12
Capacity: 190 Ah (10-hour rate to 1.80 VPC at 25C); 202 Ah (20-hour rate)
Chemistry: AGM VRLA, front terminal, standby service
Terminal: Front terminal, M6
Minimum Order Quantity: 4 Batteries
Dimensions: 22.0 x 4.96 x 12.6 in
Leoch LPF12-190 Battery - 12V 200AH Front Terminal

Leoch LPF12-190 Battery - 12V 200AH Front Terminal

$634.00
Adding to cart… The item has been added

Leoch LPF12-190 Battery - 12V 190Ah Front Terminal AGM

The LPF12-190 is Leoch's 190 Ah front-terminal standby cell, rated at the 10-hour rate to 1.80 volts per cell. At the 20-hour rate the same battery gives 202 Ah, which is where the 200 Ah figure you may have seen against this part comes from. It is a 22.0 by 4.96 by 12.6 inch case at 126.3 pounds on M6 terminals, designed to drop into a 19-inch or 23-inch power cabinet and be serviced from the front. Leoch builds the LPF range specifically for standby duty, and the warranty is written to match.

Warranty

Leoch warrants the LPF series for 36 months full replacement in standby service, in the United States and Canada. Terms are confirmed in writing with your quote.

Built for Standby, in a Front-Access Case

Front conversion terminals
M6 terminals on the front face with shielded covers against accidental short. At 126 pounds a unit, servicing from the aisle is the difference between a one-person job and a lift.
4.0 milliohm internal resistance
The baseline your IEEE 1188 ohmic trending measures drift against. Record it at commissioning, because a percentage change from a known start is the only reading that tells you anything.
Cabinet-sized footprint
560 by 126 by 320 mm, built for standard 19-inch and 23-inch power cabinets. Leoch designs the LPF case around the rack rather than the other way round.
  • 190.0 Ah nominal at the 10-hour rate to 1.80 VPC, 202.0 Ah at the 20-hour rate, 185.6 Ah at the 8-hour rate to 1.75 VPC. Three rates, one battery.
  • 1,900 A short-circuit current (5 seconds) and 127.5 A for one full hour to 1.60 VPC.
  • Compliant with IEC 60896 and the EU Battery Directive, UL and CE certified, built in IATF 16949, ISO 45001, ISO 9001 and ISO 14001 certified facilities.

Technical Specifications

Leoch LPF12-190 Specifications
Part Number LPF12-190 (also written LPF12 190, LPF 12-190; superseding the LPF12-200 designation this part was sold under earlier)
Battery Type AGM, valve regulated lead acid (VRLA), front terminal
Nominal Voltage 12V
Nominal Capacity 190.0 Ah at the 10-hour rate to 1.80 VPC at 25°C
Also Rated 202.0 Ah at the 20-hour rate (10.1 A); 185.6 Ah at the 8-hour rate to 1.75 VPC; 151.2 Ah at the 5-hour rate; 127.5 Ah at the 1-hour rate to 1.60 VPC
Short Circuit Current 1,900 A (5 seconds)
Internal Resistance Approximately 4.0 milliohms at 25°C
Terminal Type Front terminal, M6
Length 22.0 inches (560 mm, plus or minus 3 mm)
Width 4.96 inches (126 mm, plus or minus 2 mm)
Height 12.6 inches (320 mm, plus or minus 2 mm)
Weight 126.3 lbs (57.3 kg)
Standby Charging Voltage 13.5V to 13.8V at 25°C; temperature coefficient -20mV per °C
Cycle Charging Voltage 14.1V to 14.4V at 25°C; temperature coefficient -30mV per °C
Max Charging Current Less than 57.0 A
Operating Temperature Discharge -15°C to 50°C (5°F to 122°F); charge -20°C to 40°C; storage -15°C to 40°C
Capacity vs Temperature 103% at 40°C, 100% at 25°C, 86% at 0°C
Storage Up to 6 months at 25°C, then a freshening charge is required
Container ABS
Certification IEC 60896, EU Battery Directive, UL and CE certified
Warranty 36 months full (Leoch LPF warranty, standby applications, US and Canada)
Minimum Order 4 units

Where This Battery Is Used

  • UPS standby plant - the reserve string that carries the load through a transfer and a generator start.
  • 19-inch and 23-inch power cabinets - the case Leoch designed the LPF range around.
  • Telecom network connection equipment - -48V plant where front access is the maintenance requirement.
  • Local area network power systems - closet and distribution-frame reserve.
  • Power station and substation control systems - documented float duty on a scheduled inspection cycle.

Ordering and Freight

Minimum order is 4 units. At 126.3 lbs apiece these ship freight pre-paid by LTL to a commercial address; a residential or limited-access delivery adds $100, which is the liftgate and access charge the carrier bills us. Send the quantity, your delivery ZIP and your requested-by date, and a specialist returns a written quote with volume pricing in 24 to 48 hours. If you are matching an existing cabinet, send a photo of the label and the tray dimensions and we will confirm the fit before anything ships.

Frequently Asked Questions

Is this a 190 Ah battery or a 200 Ah battery?

Both, at different rates. This part has been listed under both numbers, so the distinction matters. Leoch's nameplate is 190.0 Ah at the 10-hour rate to 1.80 VPC. Size the reserve against that. At the 20-hour rate the same battery delivers 202.0 Ah, which rounds to the 200 Ah this page and its web address have carried. At the 8-hour rate to 1.75 VPC it gives 185.6 Ah. Nothing here contradicts anything else; they are four measurements of one battery. Match whichever basis your plant documentation uses.

I was quoted an LPF12-200. Is that this battery?

Yes. LPF12-200 is the superseded designation for the part Leoch now publishes as LPF12-190. Same case, same footprint, same 202 Ah at the 20-hour rate. If your records, your rack label or an old quote says LPF12-200, this is the battery you are looking for. Send us the old part number on the quote request and we will confirm it against the current datasheet in writing.

What is the internal resistance and why does it matter?

Approximately 4.0 milliohms at 25°C fully charged. On its own the number means little; as a commissioning baseline it means a lot. Record every block's reading at install, then trend the percentage change. A single block drifting 25% above its own baseline is the earliest warning you will get, and it will show up long before a capacity test would catch it.

Can I use this in a cycling application?

Leoch's warranty covers LPF batteries manufactured specifically for standby, and states plainly that it does not apply to batteries used in other applications. The battery has a published cycle charging voltage of 14.1V to 14.4V, so it will cycle, but doing so puts you outside the warranted use. If your load cycles daily, tell us and we will point you at the right series instead.

Get the LPF12-190 priced for your site

Send the quantity, your delivery ZIP and your requested-by date. A specialist confirms availability, cabinet fit, volume pricing and freight in writing, with no obligation to buy.

Call 1-877-775-4381  ·  battery specialists, not a call center

WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov (State of California only).

Customer Reviews

Customers Also Viewed