• Free Shipping

    Orders $75 & Up

  • 30-day Money Back

    Guarantee*

  • 100% Secure Online Shopping

    SSL - Verified Merchant

Deka Unigy II Spacesaver Battery Module - 24AVR125-33 (24V Config)

$32,991.02
SKU: 24AVR125-33-24
Availability: Request Quote For Availability
Shipping: Free shipping on orders $75 and up
Voltage: 24 (12 x 2V cells)
Chemistry: AGM VRLA, pure lead positive grid, IPF plates, Microcat vent
Terminal: Lead-plated copper two-way posts; top or side termination
Features: Battery Module System
Capacity: 2,000 Ah per cell (8-hour rate to 1.75 VPC at 77F)
Dimensions: System 26.60 x 28.63 in footprint; 6 modules at 26.60 x 28.63 x 11.91 in
Deka Unigy II Spacesaver Battery Module - 24AVR125-33 (24V Config)

Deka Unigy II Spacesaver Battery Module - 24AVR125-33 (24V Config)

$32,991.02
Adding to cart… The item has been added

Deka Unigy II 24AVR125-33 Spacesaver System - 24V, 2,000 Ah 2V Cells

This is the 24V configuration of the Deka Unigy II 24AVR125-33 Spacesaver system: twelve AVR125-33 cells, 2 volts and 2,000 ampere-hours each at the 8-hour rate to 1.75 volts per cell, in six two-cell Interlock modules stacked six high as a single column. East Penn's module sheet, Form 0983, puts each module at 26.60 by 28.63 by 11.91 inches and 718 lbs with cells, so the whole system stands on one 26.60 by 28.63 inch footprint and weighs 4,308 lbs in cells and modules. It is the same cell and the same module as the 48V system, halved, for the 24V plants that serve smaller switching and transmission sites.

Warranty

Warranty. East Penn's term on the Unigy II line is 3 years full replacement under E.P.M. Form 1865. Design life is a separate figure: 20 years in float service at 77°F is East Penn's published estimate for the Unigy II AVR cells. Terms are confirmed in writing with your quote.

One Column, 2,000 Ah

2,000 Ah per cell
250 amps for eight hours to 1.75 VPC at 77°F on East Penn's Form 0983, with published figures from the 3-hour to the 24-hour rate.
A single 26.60 by 28.63 inch footprint
Six modules in one column. Where the 48V system needs two columns side by side, the 24V system needs one.
4,308 lbs, six modules
Half the 48V system's weight, from East Penn's 718 lb module figure, before base and hardware.
  • Interlock module design - front bolting only, no rear access needed, front shield fitted without tools.
  • Seismic note on the AVR125 - East Penn's flyer certifies AVR125 modules to NEBS Zone 4 up to three modules high; this six-high column is reviewed against the site's seismic requirement with the quote.
  • Constant-power figures published - 3,434 watts per cell at the 15-minute rate to 1.67 VPC, so the cell also serves a 24V high-rate duty.
  • IEC 60896-21/22, BS 6290, SR-4228 - the standards East Penn designs the Unigy II line to meet; UL recognized component.
  • Top or side termination - standard option at no extra cost; side termination adds 3 inches per side to length.
  • Float voltage published - 2.25 volts per cell plus or minus 0.01, which is 27.0V nominal for a 12-cell string, with charger settings from the Unigy II manual.

Technical Specifications

Deka Unigy II 24AVR125-33 (24V) System Specifications
Part Number24AVR125-33, 24V configuration (also searched as 24AVR125 24, AVR125-33 24V, deka unigy ii 24 volt)
System Voltage24V nominal, 12 cells in series
CellAVR125-33, 2V, 33 plates per cell, AGM VRLA
Capacity, 8-hour rate2,000 Ah per cell to 1.75 VPC at 77°F (East Penn Form 0983: 250 A for 8 hours)
Discharge, 5-hour rate352 A to 1.75 VPC
Discharge, 12-hour rate182 A to 1.75 VPC
Constant Power, 15-minute rate3,434 W per cell to 1.67 VPC
ModuleTwo cells per module, 4V; 26.60 in long, 28.63 in deep, 11.91 in high; 718 lbs (326 kg) with cells, excluding hardware and base
ArrangementSingle stack, 6 modules high, Interlock
System Footprint26.60 in long by 28.63 in deep; add 6 in to length for side termination
Stack HeightApproximately 64 in for six modules per East Penn's stacking formula, before the 4 in base, 1.5 in termination bracket and 6.25 in top shield
System Weight4,308 lbs, cells and modules (6 x 718 lbs); base and hardware additional
Specific Gravity1.300
Float Voltage2.25 VPC ±0.01 (27.0V nominal for 12 cells)
ContainerFlame-retardant polypropylene, UL 94 V-0, LOI 28% or greater
SeismicNEBS Zone 4 certified to 3 modules high (East Penn); 6-high stack reviewed at quote
StandardsIEC 60896-21/22, BS 6290, SR-4228 (designed to meet); UL recognized component
Design Life20 years in float service at 77°F (East Penn, Unigy II)
Warranty3 years full replacement (East Penn, Unigy II, Form 1865)

Where This System Is Used

  • 24V telecom and transmission plants - microwave, radio and transport sites that run a 24V DC bus and need long reserve at high capacity.
  • Utility control power at 24V - substation and switchgear duty where the plant standard is 24V rather than 48.
  • Sites with one column of floor space - the single-stack footprint fits a corner the double stack does not.

Ordering and Freight

A 24V AVR125-33 system ships as cells, modules, base and hardware on pallets, freight pre-paid by LTL or dedicated truck to a commercial address with a dock or forklift; a residential or limited-access delivery adds $100, which is the liftgate and access charge the carrier bills us. Send the site address, floor loading and door clearances, top or side termination, and your requested-by date, and a specialist returns a written quote with the system drawing in 24 to 48 hours.

Frequently Asked Questions

Can a 24V system be expanded to 48V later?

In principle the 48V system is two of these columns wired in series, twelve modules for twenty-four cells. In practice a string should be built from cells of the same age, so adding a second column years later puts new cells in series with aged ones and the string performs to its weakest cells. If a move to 48V is likely within a year or two, tell a specialist now; it may be better to buy the 48V system at once, or to plan the second column as a separate string.

What reserve does 2,000 Ah give a 24V plant?

The same hours as any string of these cells at a given current, because a series string carries the cell current. East Penn's table gives 250 amps for 8 hours, 352 amps for 5 hours, and 182 amps for 12 hours, all to 1.75 volts per cell at 77°F. Your plant's DC load in amps is the string current; find it in the table and read the hours across. Send the load and a specialist confirms the reserve against the published row.

Does the 28.63 inch depth include the front shield?

Yes. East Penn's footnote on Form 0983 states the module depth figure includes the front shield. Door and aisle clearances should be checked against the 28.63 inch figure, and against 26.60 inches plus 6 inches if you specify side termination, which adds 3 inches on each side.

Does the 24V system use the same manual as the 48V?

Yes. Both are Interlock module systems and both follow East Penn's Unigy II Interlock installation and operation manual, 2024 edition, linked above. Float voltage, charger current, torque values and commissioning tests are the same per cell; only the cell count and the bus voltage differ. Our installation service, if you take it with the quote, works from that manual.

Same cell, 48V plantThe 48V configuration of the 24AVR125-33 doubles the column: twenty-four cells in twelve modules.
Get the 24AVR125-33 24V system priced for your plant

Send the site address, clearances, termination preference and your requested-by date. A specialist confirms availability, the warranty term, pricing, freight and the system drawing in writing, with no obligation to buy.

Call 1-877-775-4381  ·  battery specialists, not a call center

WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov (State of California only).

Customer Reviews

Customers Also Viewed