CSB UPS12460F2 Battery 12V 460W - High-Rate AGM F2 Terminal

$25.95
SKU: UPS12460F2
Availability: Contact For Availability
Shipping: Free shipping on orders $75 and up
Voltage: 12
Capacity: 9 Ah
Chemistry: AGM VRLA
Terminal: F2 faston tab 250
Features: High-Rate Series
Watts Per Unit: 460 W at 5 min to 1.60 VPC
Dimensions: 5.94 x 2.55 x 3.88 in
CSB UPS12460F2 Battery 12V 460W - High-Rate AGM F2 Terminal

CSB UPS12460F2 Battery 12V 460W - High-Rate AGM F2 Terminal

$25.95

Out of stock

CSB UPS12460 F2 Battery - 12V 460W High Rate AGM

This is a compact, economical, high-rate AGM that does one job well: hold a desktop or rack UPS up for the few minutes it takes to shut down cleanly. One number matters before anything else: the 460 in the part number is watts per unit at the 5-minute rate to 9.60V, not amp hours - this is a 9Ah battery, and CSB's own datasheet prints that basis in its Nominal Capacity row. At 5.94 by 2.55 by 3.88 inches and 5.5 lbs with F2 faston tabs, it is the standard replacement cell inside a great many single-phase UPS cabinets. CSB builds it on pure lead with proprietary elements and lists it to UL 1973. If you arrived here needing a 12V 460Ah battery, this is not that part - call us and we will point you at the right one.

Warranty

CSB warrants the UPS series for 1 year. Design life is a separate figure: 5 years at 25°C. Country of origin is Vietnam. Terms are confirmed in writing with your quote.

What You Get

130 A for 5 seconds
Max discharge current. This is a high-rate cell, which is why it holds voltage through the inverter's first demand instead of sagging into a fault.
Pure lead construction
CSB builds the UPS series on pure lead with proprietary elements, which is what lets a cell this small still take a hard discharge without shedding.
UL 1973 listed, UL 1989 recognized
File MH66728 and MH14533, built to IEC 61056-1/2:2012, TUV NORD certified to ISO 9001:2015. Both listings are current.
  • Less than 10% self-discharge after 90 days - storable up to 6 months, or 10 months with an equalization charge.
  • Maintenance-free AGM with up to 99% gas recombination. No watering, no topping up, mountable in any orientation but inverted.
  • Bulk pricing available. There is no minimum order on this part, but the price moves meaningfully at quantity - most buyers are doing a whole cabinet or a fleet.

Technical Specifications

CSB UPS12460 F2 Specifications
Part Number UPS12460F2 (CSB catalog part UPS12460; the F2 denotes the terminal. Also written UPS12460 F2 and searched as 12460 F2)
Battery Type AGM, valve regulated lead acid (VRLA), pure lead construction
Nominal Voltage 12V
Nominal Rating 460 W per unit at the 5-minute rate to 9.60V at 25°C - watts, not amp hours
Also Rated 74.00 W per cell at 5 min to 1.67 VPC (444 W per unit); 36.83 W per cell at 15 min to 1.67 VPC
Amp-Hour Equivalent 9Ah nominal, per CSB distributor data. CSB's datasheet rates this unit in watts and publishes no amp-hour figure.
Max Discharge Current 130 A (5 seconds)
Max Charge Current 3.80 A
Short Circuit Current 450 A
Internal Resistance Approximately 16.60 milliohms
Terminal Type F2 faston tab 250
Length 5.94 inches (150.9 mm)
Width 2.55 inches (64.8 mm)
Height 3.88 inches (98.6 mm)
Weight 5.51 lbs (2.50 kg)
Float Charging Voltage 13.5 to 13.8 Vdc per battery at 25°C
Equalize Charging Voltage 14.4 to 15.0 Vdc per battery at 25°C
Operating Temperature Discharge -15°C to 50°C (5°F to 122°F); charge and storage -15°C to 40°C
Container ABS, UL 94-HB (flame retardant UL 94 V-0 available on request)
Certification UL 1973 listed (MH66728), UL 1989 recognized (MH14533), IEC 61056-1/2:2012, TUV NORD ISO 9001:2015
Design Life Up to 5 years standby at 25°C; Eurobat (20°C) 3 to 5 years, standard commercial
Warranty 1 year (CSB Small UPS class)
Country of Origin Vietnam
Technical Documentation

Where This Battery Is Used

  • Single-phase rack and tower UPS - the replacement cell inside a great many 1kVA to 3kVA cabinets.
  • Desktop and workstation UPS - clean-shutdown power for a machine you do not want to lose work on.
  • Point-of-sale and small server closets - where the UPS is the only backup and nobody notices it until it fails.
  • Security, access control and alarm panels - small standby loads on a maintained float charge.
  • Emergency lighting and signage - code-driven backup on a replacement cycle.

Ordering

No minimum order, and bulk pricing is where this part gets interesting. Most people buying a UPS12460F2 are doing a whole cabinet or refreshing a fleet on a cycle. Send the quantity and your delivery ZIP and a specialist returns volume pricing in 24 to 48 hours. If you are refreshing on a schedule, ask about the date code - CSB stamps manufacture date on every cell and we will tell you what you are getting rather than shipping you old stock.

Frequently Asked Questions

Is the UPS12460F2 a 460Ah battery?

No. It is a 9Ah battery. The 460 is watts per unit at the 5-minute rate to 9.60 volts, which is how CSB rates its high-rate UPS series and how UPS manufacturers size strings. CSB's datasheet prints this in the Nominal Capacity row. This is the single most common misunderstanding on this part and it is worth being blunt about: 460 amp hours in this case size is not physically possible.

Why do I see different watt figures quoted for this battery?

Because there are three real numbers and people quote them interchangeably. 460 W per unit at 5 minutes to 9.60V is the nameplate. 444 W per unit (74.00 per cell) is the same discharge measured to 1.67 VPC. 221 W per unit (36.83 per cell) is the 15-minute rate. All three are correct measurements of the same battery; they are not interchangeable, and at least one published CSB catalog has mislabelled which is which. Size against whichever basis your UPS documentation specifies.

Will this fit my UPS?

Check three things: the case is 5.94 by 2.55 by 3.88 inches, the terminals are F2 faston tabs, and the rating is 460W at the 5-minute rate. If your existing cell matches all three, this drops in. F2 and the narrower F1 tab are not interchangeable without an adapter, so check the tab width before ordering.

Why is the warranty only one year?

Because CSB classifies this as a Small UPS product, and one year is the class standard rather than a mark against this particular cell. The design life is 5 years at 25°C. In practice these get replaced on a three-to-five year cycle in any environment that matters, and the honest way to buy them is on price and date code rather than on warranty length.

How do I check how old the battery is?

CSB stamps a date code on every cell. The statement linked above explains how to read it. Ask us for the current date code before you order if you are stocking spares - a battery that has sat on a shelf for a year has already spent part of its life.

Get the UPS12460 F2 priced at your quantity

Send the quantity and your delivery ZIP. A specialist confirms availability, current date code and volume pricing in writing, with no obligation to buy.

Call 1-877-775-4381  ·  battery specialists, not a call center