• Free Shipping

    Orders $75 & Up

  • 30-day Money Back

    Guarantee*

  • 100% Secure Online Shopping

    SSL - Verified Merchant

C&D TEL12-105FNSG True Front Access 12V 104Ah Telecom Battery

$541.95
SKU: TEL12-105FNSG
Availability: Request Quote For Availability
Minimum Purchase: 4 units
Shipping: Free shipping on orders $75 and up
Voltage: 12
Capacity: 104 AH
Chemistry: AGM
Features: TEL Long Duration Series
Terminal: Front Terminal
C&D TEL12-105FNSG True Front Access 12V 104Ah Telecom Battery
C&D TEL12-105FNSG True Front Access 12V 104Ah Telecom Battery
$541.95
Adding to cart… The item has been added

C&D TEL12-105FNSG Battery - 12V Long Duration Front Access AGM

The TEL12-105FNSG is a roughly 100 amp hour True Front Access monobloc in C&D's TEL Long Duration line, rated 104 Ah at the 8-hour rate to 1.75 volts per cell and 102 Ah at the 10-hour rate. M6 terminals at the face of the case keep string service in the aisle, and the standard-AGM TEL construction carries C&D's Telcordia-certified life exceeding 10 years.

Warranty

C&D's warranty term for this model is confirmed in writing with your quote. Design life is a separate figure: Telcordia-certified, exceeding 10 years for the series.

104 Ah, M6 Front Terminals

104 Ah at the 8-hour rate
The reserve rating that sizes a telecom string, with 102 Ah at the 10-hour rate to 1.80 volts per cell.
M6 front terminals
Threaded hardware presented forward, so torque checks and voltage readings never require pulling a unit.
4,000 A short-circuit rating
With 3.0 milliohms of internal resistance, the fault numbers your protection sizing starts from.
  • Sealed AGM VRLA - long-duration plates for multi-hour discharges, nothing to water, non-spillable.
  • SR-4228, UL 1989, UL 1778, UL 924, UL 94 V-0 - the TEL series certification set, published by C&D.
  • Front-access string layout - built for relay-rack trays where every connection faces the aisle.

Technical Specifications

C&D TEL12-105FNSG Specifications
Part NumberTEL12-105FNSG (also searched as TEL12-105FNS, TEL12 105FNSG)
Battery TypeAGM VRLA, front access, long-duration telecom standby
Nominal Voltage12V
Capacity, 8-hour rate104 Ah to 1.75 VPC
Capacity, 10-hour rate102 Ah to 1.80 VPC
Short Circuit Current4,000 A
Internal Resistance0.0030 ohm
Terminal TypeM6 threaded, front access
CertificationsSR-4228, UL 1989, UL 1778, UL 924, UL 94 V-0 (TEL series)
Length15.63 inches (397 mm)
Width4.17 inches (106 mm)
Height11.30 inches (287 mm)
Weight71 lbs (32 kg)
Terminal TorqueM6 at 107 in-lbs (12 N-m)
Operating TemperatureDischarge -40°F to +160°F; charge -10°F to +140°F
Float Charging Voltage13.5 to 13.8 VDC average per 12V unit at 77°F
StorageUp to 6 months at 77°F before a freshening charge is required
Design LifeTelcordia-certified, exceeding 10 years (C&D, TEL series)
WarrantyConfirmed in writing with your quote (C&D)

Where This Battery Is Used

  • -48V telecom strings - four 12V monoblocs per string, the standard plant building block.
  • Relay-rack battery shelves - front-terminal trays in central offices and remote terminals.
  • Conditioned outside plant - cabinets and huts where the standard TEL build is the right economics.

Ordering and Freight

At 71 lbs per unit, string quantities ship freight pre-paid by LTL to commercial addresses; a residential or limited-access delivery adds $100, which is the liftgate and access charge the carrier bills us. A specialist returns a written quote with volume pricing in 24 to 48 hours.

Frequently Asked Questions

Is my part number TEL12-105FNS or TEL12-105FNSG?

Both forms circulate in purchasing records, and our catalog lists the FNSG build, which is what C&D's published TEL data covers. Suffix letters matter on this line because they encode the build, so send a photo of the label on the unit coming out with your quote request and the specialist confirms the exact match in writing before anything is ordered.

How does the FNSG compare with the TEL12-115FN?

They are neighbors in the same line: 104 Ah against 108 Ah at the 8-hour rate, the same M6 front-terminal hardware, the same 4,000 A short-circuit class. The cases differ, though: the FNSG is 15.63 inches long and 11.30 tall, the 115FN 20.12 long and 9.25 tall, so one does not drop into the other's tray position. In practice the choice is made by what the string already contains and what the tray was drawn for, so match the existing model on a refresh and let the specialist confirm footprint on a new build.

What do the TEL series certifications cover?

C&D publishes the set for the TEL Long Duration series: SR-4228, UL 1989, UL 1778 and UL 924, with a UL 94 V-0 case and cover. C&D also lists the battery as a UL-recognized component.

What equalize voltage does C&D specify?

14.40 to 14.80 VDC average per 12V unit at 77°F, against a float of 13.5 to 13.8.

The same class for hot sitesThe TEL12-105FHTG carries 101 Ah in C&D's high-temperature TEL-HT construction.
Get the TEL12-105FNSG priced for your string

Send the quantity, your delivery ZIP and your requested-by date. A specialist confirms availability, the warranty term, volume pricing and freight in writing, with no obligation to buy.

Call 1-877-775-4381  ·  battery specialists, not a call center

WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov (State of California only).