C&D TEL12-180F TEL Front Access Series Battery

$669.95
SKU: TEL12-180F
Availability: Request Quote For Availability
Minimum Purchase: 4 units
Shipping: Free shipping on orders $75 and up
Voltage: 12
Capacity: 181 AH
Chemistry: AGM
Features: High-Rate Series
Terminal: Front Terminal
C&D TEL12-180F TEL Front Access Series Battery

C&D TEL12-180F TEL Front Access Series Battery

$669.95
Adding to cart… The item has been added

C&D TEL12-180F Battery - 12V 181Ah Front Access Telecom AGM

The TEL12-180F sits near the top of C&D's TEL Long Duration range: a 12V front-access monobloc rated 181 Ah at the 8-hour rate to 1.75 volts per cell, with 174 Ah at the 10-hour rate. Fewer, larger monoblocs mean fewer intercell connections in the string, and the front-access build keeps every one of them serviceable from the aisle. This is the class of battery that holds a full central office plant through a long outage rather than a short blip.

Warranty

Warranty. The C&D term on our TEL telecom batteries is 6 years. Design life is a separate figure: the TEL series carries C&D's Telcordia-certified life exceeding 10 years. Terms are confirmed in writing with your quote.

Big Reserve, Fewer Joints

181 Ah at the 8-hour rate
One of the largest capacities in the TEL line, for strings that must carry the plant through hours, not minutes.
1/4-20 threaded terminals
Bolted lug connections rated for the current a monobloc this size moves, torqued and read from the front of the case.
3.7 milliohm internal resistance
With a 4,500 A short-circuit figure, the fault characteristics your protection engineer sizes breakers against.
  • Sealed AGM VRLA - non-spillable long-duration design, nothing to water, nothing to vent maintain.
  • TEL series certification set - SR-4228, UL 1989, UL 1778, UL 924 and the UL 94 V-0 case rating.
  • Front-access string service - readings and retorques happen without unracking a 12V monobloc of this size.

Technical Specifications

C&D TEL12-180F Specifications
Part NumberTEL12-180F (C&D's current catalog lists the model as TEL12-180Fa; also searched as TEL12 180F)
Battery TypeAGM VRLA, front access, long-duration telecom standby
Nominal Voltage12V
Capacity, 8-hour rate181 Ah to 1.75 VPC
Capacity, 10-hour rate174 Ah to 1.80 VPC
Short Circuit Current4,500 A
Internal Resistance0.0037 ohm
Terminal Type1/4-20 threaded, front access
CertificationsSR-4228, UL 1989, UL 1778, UL 924, UL 94 V-0 (TEL series)
Length22.01 inches (559 mm)
Width4.96 inches (126 mm)
Height12.60 inches (320 mm)
Weight132 lbs (60 kg)
Terminal Torque1/4-20 at 110 in-lbs (12.4 N-m)
Operating TemperatureDischarge -40°F to +160°F; charge -10°F to +140°F
Float Charging Voltage13.5 to 13.8 VDC average per 12V unit at 77°F
StorageUp to 6 months at 77°F before a freshening charge is required
Design LifeTelcordia-certified, exceeding 10 years (C&D, TEL series)
Warranty6 years (C&D)

Where This Battery Is Used

  • Central office plants - the -48V reserve where fewer, larger monoblocs simplify the string.
  • Aggregation and headend sites - long-duration holdover for the equipment a region depends on.
  • Standby plants with long generator starts - sites where the battery bridges more than a transfer switch click.

Ordering and Freight

At 132 lbs per unit these ship freight pre-paid by LTL to commercial addresses; a residential or limited-access delivery adds $100, which is the liftgate and access charge the carrier bills us. Send the quantity, your delivery ZIP and your requested-by date, and a specialist returns a written quote with volume pricing in 24 to 48 hours.

Frequently Asked Questions

Is TEL12-180F the same battery as TEL12-180Fa?

C&D's current published catalog lists the model as TEL12-180Fa, and the 181 Ah rating class is the same. Manufacturers revise suffix letters between catalog generations, and the label on the delivered unit reflects current production. If your records or your existing string say 180F, send the label photo with your quote request and the specialist confirms the exact build in writing before anything ships.

What does the 4,500 A short-circuit figure mean for my install?

It is a fault characteristic, separate from any usable rating. That number tells your protection engineer what a bolted fault across the terminals can deliver, which sizes the overcurrent protection and the cable. Reserve time still comes from the amp-hour ratings, so size the string from the 8-hour figure and the load, and leave the 4,500 A to the breaker calculation.

What connects to a 1/4-20 terminal?

A bolted cable lug on a threaded copper-alloy insert, which is how C&D terminates its larger TEL monoblocs; the smaller models in the line use M6 hardware instead. Use the washer stack and torque figure from the install drawing for your build, and confirm lug sizing with the quote if you are replacing hardware along with the batteries.

Hot site? The same class in pure leadThe TEL12-190FHT carries 199 Ah with C&D's high-temperature MSE construction.
Get the TEL12-180F priced for your plant

Send the quantity, your delivery ZIP and your requested-by date. A specialist confirms availability, the warranty term, volume pricing and freight in writing, with no obligation to buy.

Call 1-877-775-4381  ·  battery specialists, not a call center

WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov (State of California only).

Customer Reviews

Customers Also Viewed