• Free Shipping

    Orders $75 & Up

  • 30-day Money Back

    Guarantee*

  • 100% Secure Online Shopping

    SSL - Verified Merchant

C&D Technologies TEL12-105FHTG 12V 101Ah Front Access AGM Battery

$490.00
SKU: TEL12-105FHTG
Availability: Request Quote For Availability
Minimum Purchase: 4 units
Shipping: Free shipping on orders $75 and up
Capacity: 101 Ah
Chemistry: AGM
Type: Front Terminal
Dimensions: 16.2 × 4.2 × 11.4
Weight: 72 lbs
C&D Technologies TEL12-105FHTG 12V 101Ah Front Access AGM Battery

C&D Technologies TEL12-105FHTG 12V 101Ah Front Access AGM Battery

$490.00
Adding to cart… The item has been added

C&D TEL12-105FHTG Battery - 12V 101Ah TEL-HT Front Access

The TEL12-105FHTG is the compact monobloc in C&D's high-temperature TEL-HT line: 12V, 101 Ah at the 8-hour rate, on a 16.2 by 4.2 by 11.4 inch footprint at 72 lbs that fits standard 19-inch and 23-inch relay racks. It is built on MSE pure lead grids, rated for discharge from -40°F to +160°F with a 12+ year design life, and the G in the part number is real hardware: the TFA gas collection system, marked on C&D's own datasheet.

Warranty

Warranty. C&D's term on our TEL telecom batteries is 6 years, this model included. Design life is a separate figure: 12+ years per the TEL-HT datasheet. Terms are confirmed in writing with your quote.

The Compact High-Temperature Build

101 Ah in 16.2 inches
The shortest case among our stocked TEL-HT models, sized for rack shelves the 22-inch monoblocs cannot enter.
TFA gas collection
The G-suffix hardware C&D marks on the datasheet, collecting vented gas at the True Front Access terminals.
-40°F to +160°F discharge
The full TEL-HT operating window, built for enclosures that never see conditioned air.
  • MSE pure lead construction - the grid technology behind the line's 12+ year design life rating.
  • M6 front terminals at 90 in-lbs - threaded copper-alloy inserts, serviced from the aisle.
  • 800 A maximum discharge - with 6.5 milliohms impedance at 60 Hz.
  • Two-year storage rating - up to 24 months at 77°F before a freshening charge is required.

Technical Specifications

C&D TEL12-105FHTG Specifications
Part NumberTEL12-105FHTG (also searched as TEL12 105FHTG, C&D 105FHTG)
Battery TypeVRLA-AGM, MSE pure lead, front access, high-temperature telecom standby
Nominal Voltage12V
Capacity, 8-hour rate101 Ah to 1.75 VPC at 77°F
IEC Capacity, 10-hour rate98 Ah to 1.80 VPC at 68°F
Maximum Discharge Current800 A
Impedance0.0065 ohm at 60 Hz
Terminal TypeThreaded copper alloy insert, M6 bolt at 90 in-lbs (10.2 N-m)
Gas ManagementTFA gas collection system (C&D datasheet designation for G-suffix models)
Length16.2 inches (412 mm)
Width4.2 inches (106 mm)
Height11.4 inches (289 mm)
Weight72 lbs (32.8 kg)
Operating TemperatureDischarge -40°F to +160°F; charge -10°F to +140°F
Float Charging Voltage13.65 VDC ±0.15 per 12V unit
Design Life12+ years (C&D, TEL-HT datasheet REV 04/03/24)
Warranty6 years (C&D)
Technical Documentation

Where This Battery Is Used

  • Cell sites and outdoor cabinets - the 100 Ah class where summer heat rules out standard VRLA.
  • 19-inch and 23-inch relay racks - the short case slides where longer TEL-HT models will not.
  • Enclosures with gas management requirements - installs that call for collected venting at the terminal face.

Ordering and Freight

At 72 lbs per unit, string orders ship freight pre-paid by LTL to commercial addresses; a residential or limited-access delivery adds $100, which is the liftgate and access charge the carrier bills us. Send the quantity, your delivery ZIP and your requested-by date, and a specialist returns a written quote with volume pricing in 24 to 48 hours.

Frequently Asked Questions

What does the G at the end of the part number mean?

It marks the TFA gas collection system, the hardware C&D flags on the TEL-HT datasheet for this model and the 170FHTG. Instead of venting diffusely, the battery routes gas through a collection path at the front-access terminals, which some enclosure designs and site specifications require. If your spec is silent on gas collection, the hardware is simply built in on this model and stays out of the way.

Can this replace my TEL12-105FNSG?

Same brand, same 100 Ah class, different construction and case. The FHTG brings pure lead grids, the extended temperature window and the 12+ year design life; the tray, however, decides. Send your shelf dimensions and the label of the unit coming out with the quote request, and the specialist confirms fit and hardware in writing before you commit either way.

Does a 101 Ah battery need an 800 A discharge rating?

Rarely at full stretch, by design. The 800 A ceiling keeps the battery clear of becoming the limit during inrush, fault clearing or a hard transfer, and a standby battery does its best work running far below its maximum rating. Reserve time still comes from the amp-hour figures, so size the string from the 8-hour rating.

Browse the telecom battery catalogEvery brand and duty class we stock for -48V plants, cabinets and standby strings.
Get the TEL12-105FHTG priced for your racks

Send the quantity, your delivery ZIP and your requested-by date. A specialist confirms availability, the warranty term, volume pricing and freight in writing, with no obligation to buy.

Call 1-877-775-4381  ·  battery specialists, not a call center

WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov (State of California only).

Customer Reviews

Customers Also Viewed