Free Shipping
Orders $75 & Up
-
30-day Money Back
Guarantee*
-
100% Secure Online Shopping
SSL - Verified Merchant
Leoch LPF12-150B Battery - 12V 150Ah Front Terminal
Leoch LPF12-150B Battery - 12V 150Ah Front Terminal
Leoch LPF12-150B Battery - 12V 150Ah Front Terminal AGM
Warranty
Built for Standby, in a Front-Access Case
- 150 Ah nominal at the 10-hour rate to 1.80 VPC at 25°C, per Leoch publication LB-LPF12-150-PD-EN-V2.0.
- 2,400 A short-circuit current, with a maximum charging current of 0.3C.
- Compliant with IEC 60896 and the EU Battery Directive, UL and CE approved, built in IATF 16949, ISO 45001, ISO 9001 and ISO 14001 certified facilities.
Technical Specifications
| Leoch LPF12-150B Specifications | |
|---|---|
| Part Number | LPF12-150B (also written LPF12 150B, LPF 12-150B; Leoch publishes the cell datasheet as LPF12-150. The B designates the T13 terminal and minor outer case details; the electrical ratings are the LPF12-150's.) |
| Battery Type | AGM, valve regulated lead acid (VRLA), front terminal |
| Nominal Voltage | 12V |
| Nominal Capacity | 150 Ah at the 10-hour rate to 1.80 VPC at 25°C |
| Short Circuit Current | 2,400 A |
| Internal Resistance | Approximately 4.3 milliohms at 25°C, fully charged |
| Terminal Type | T13 front terminal: M6 thread, tin-plated copper alloy insert |
| Length | 21.7 inches (551 mm) |
| Width | 4.33 inches (110 mm) |
| Height | 11.3 inches (288 mm), container and total height the same |
| Weight | 98.8 lbs (44.8 kg) |
| Float Charging Voltage | 2.25 to 2.30 V per cell at 25°C (13.5V to 13.8V per battery); temperature coefficient -3mV per cell per °C |
| Equalization Charging Voltage | 2.35 to 2.40 V per cell at 25°C (14.1V to 14.4V per battery); temperature coefficient -5mV per cell per °C |
| Max Charging Current | 0.3C at 25°C |
| Operating Temperature | Discharge -15°C to 50°C (5°F to 122°F); charge -20°C to 40°C; storage -15°C to 40°C |
| Nominal Operating Temperature | 25°C plus or minus 3°C (77°F plus or minus 5°F) |
| Capacity vs Temperature | 103% at 40°C, 100% at 25°C, 86% at 0°C |
| Self-Discharge | 3% or less per month at 25°C; storable up to 6 months, then a freshening charge is required |
| Container | ABS, UL 94-HB standard, UL 94 V-0 optional |
| Certification | IEC 60896, EU Battery Directive, UL and CE approved |
| Design Life | Over 12 years at 25°C (77°F) |
| Warranty | 36 months full (Leoch LPF warranty, standby applications, US and Canada) |
| Minimum Order | 4 units |
Where This Battery Is Used
- UPS standby plant - the reserve string that carries the load through a transfer and a generator start.
- 19-inch and 23-inch power cabinets - the case Leoch designed the LPF range around.
- Telecom network connection equipment - -48V plant where front access is the maintenance requirement.
- Local area network power systems - closet and distribution-frame reserve.
- Power station and substation control systems - documented float duty on a scheduled inspection cycle.
Ordering and Freight
Frequently Asked Questions
Is this 150 Ah or 155 Ah?
Leoch rates it at 150 Ah at the 10-hour rate to 1.80 VPC. The string 155 does not appear anywhere in Leoch's datasheet for this cell, publication LB-LPF12-150-PD-EN-V2.0. The 155 attached to this listing comes from the GNB Marathon M12V155FT, the part most buyers arrive here to replace. If your specification calls for 155 Ah because that is what the outgoing battery was rated, size against 150 Ah and tell us the runtime you need, and we will confirm whether the five-amp-hour difference matters at your load.
Will it fit where a GNB Marathon M12V155FT sits?
Send us the tray dimensions and we will confirm it in writing before anything ships. Fitment is four numbers, not one: length, width, height and terminal position all have to work, and a capacity match on paper tells you nothing about whether a case slides into a fixed shelf. This is a specialist check we do on the quote, not something worth guessing from a table.
How is a 12-year design life different from a 36-month warranty?
Design life is Leoch's engineering estimate of service years under ideal float at 25°C, and for the LPF range that is over twelve years. The warranty is the 36-month period in which Leoch will replace a failed battery. The gap is normal across the industry and it is not a catch.
Can I use this in a cycling application?
Leoch's warranty covers LPF batteries manufactured specifically for standby, and states plainly that it does not apply to batteries used in other applications. It will cycle, but doing so puts you outside the warranted use. If your load cycles daily, tell us and we will point you at the right series instead.
Send the quantity, your delivery ZIP and your requested-by date. A specialist confirms availability, cabinet fit, volume pricing and freight in writing, with no obligation to buy.
Call 1-877-775-4381 · battery specialists, not a call centerWARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov (State of California only).