Voltage: 12
Capacity: 40.00 Ah (20-hour rate to 1.75 VPC at 25C); 31.52 Ah at the 8-hour rate
Chemistry: AGM VRLA, pure lead construction
Features: CSB EVX12400 shipped as an Interstate SLA1161 case replacement; confirm amp hours against your label
Terminal: I2 threaded insert, M6 bolt, 44.9 +/- 9.0 lbf-in
Dimensions: 7.76 x 6.50 x 6.71 in (L x W x H)
EVX12400 12V 40Ah Battery - Interstate SLA1161 Replacement

EVX12400 12V 40Ah Battery - Interstate SLA1161 Replacement

$133.95
Adding to cart… The item has been added

Interstate SLA1161 Replacement - CSB EVX12400 12V 40Ah AGM

This page ships a CSB EVX12400, a 12 volt deep cycle AGM rated 40.00 amp hours at the 20 hour rate to 1.75 volts per cell at 25°C. It is offered here as a replacement for the Interstate SLA1161 because the case matches: 7.76 inches long by 6.50 wide standing 6.71 tall, on a threaded insert, in the footprint that slot was built around. Capacity is the part to check before you order. Interstate has rated batteries in this case size above 40 amp hours, so read the label on the block coming out and compare it to the 40.00 figure here rather than assuming the sizes track. Where the number on your old label is higher, the CSB EVX12520 at 52 amp hours is the one to quote instead, and a specialist will tell you which of the two fits your tray. The EVX12400 runs 29.07 lbs and carries 8.2 milliohms of internal resistance with 400 cycles at full depth of discharge behind it.

Warranty

Warranty. CSB gives 1 year on the EVX High Cycle range, and this page ships the CSB part. Design life is a separate figure: 8 years per the CSB price list, measured at 25°C (77°F). Country of origin is Vietnam. Terms are confirmed in writing with your quote.

What You Are Actually Buying

A CSB EVX12400, not a relabel
The block that ships carries CSB's own part number and its own published datasheet, so every figure on this page can be checked against the manufacturer.
40.00 Ah at the 20 hour rate
Measured to 1.75 volts per cell at 25°C, with 31.52 Ah at the 8 hour rate. Compare this against your old label before ordering.
7.76 by 6.50 by 6.71 inches
The dimension set that decides a drop-in, on an I2 threaded insert taking an M6 bolt at 44.9 lbf-in.
  • Check the amp hours on the old label first - a matching case does not guarantee a matching rating, and this is the single thing that catches people out on a cross-reference.
  • 1,800 cycles at 30 percent depth of discharge - against 400 cycles at a full 100 percent, both at 25°C, which is how CSB rates life on this range.
  • 400 amps over 5 seconds - the published peak discharge, with 1,082 amps of short circuit current behind it.
  • No float charging voltage is published - CSB prints a dash in that row for the EVX range, so this block belongs in cycling duty rather than permanent float standby.
  • 12.00 amps maximum charge current - worth checking against the charger already in the equipment before the block goes in.

Technical Specifications

CSB EVX12400 Specifications
Part ShippedCSB EVX12400 (also written EVX 12400 and evx12400)
Offered As A Replacement ForInterstate SLA1161, on case dimensions; confirm the amp hour rating on your existing label
SeriesEVX, High Cycle, 12 volt top terminal
Battery TypeAGM, valve regulated lead acid (VRLA), pure lead construction
Nominal Voltage12V
Capacity, 20 Hour Rate40.00 Ah to 1.75 VPC at 25°C
Capacity, 8 Hour Rate31.52 Ah to 1.75 VPC at 25°C; 30.56 Ah to 1.80 VPC
Cycle Life400 cycles at 100 percent depth of discharge; 1,800 cycles at 30 percent, both at 25°C
Maximum Charge Current12.00 A
Maximum Discharge Current400 A over 5 seconds
Short Circuit Current1,082 A
Internal ResistanceApproximately 8.2 milliohms
Terminal TypeI2 threaded insert to accept an M6 bolt per the CSB datasheet; the CSB price list records the standard terminal as B2 / I, so confirm the terminal with your quote
Terminal Torque44.9 ± 9.0 lbf-in (5.1 ± 1.0 N·m)
Length7.76 ± 0.08 inches (197.0 ± 2.0 mm)
Width6.50 ± 0.08 inches (165.0 ± 2.0 mm)
Height6.71 ± 0.08 inches (170.4 ± 2.0 mm)
Weight29.07 lbs (13.20 kg)
BCI Group SizeM40 (CSB price list)
Float Charging VoltageNot published by CSB for the EVX range
Equalization Charging Voltage14.4 to 15.0 VDC per battery at 25°C (77°F)
Operating TemperatureNominal 25°C (77°F); discharge -15°C to 50°C (5°F to 122°F); charge and storage -15°C to 40°C (5°F to 104°F)
StandardsIEC 60254-1:2005 and IEC 60254-2:2008; UL1973 Listed (MH66728); UL1989 Recognized (MH14533); TUV NORD to ISO 9001:2015
Design Life8 years at 25°C per the CSB price list; the per-part datasheet states cycle life instead of years
Warranty1 year (CSB, EVX High Cycle range)
Country of OriginVietnam
Technical Documentation

Where This Battery Is Used

  • Powered wheelchairs and mobility scooters - the duty CSB names first for the EVX range, and the most common home for a battery in this case.
  • Patient lifts and medical transport equipment - daily cycling on a fixed charge routine rather than standby.
  • Utility electric vehicles and floor machines - packs drawn down over a shift and recharged overnight.

Ordering and Freight

The EVX12400 is a non-stock line, so quantities are confirmed with a lead time rather than shipped from the shelf. At 29.07 lbs a single block moves by parcel carrier and a multi-block pack palletizes to LTL, where a residential or limited-access delivery adds $100, the liftgate and access charge the carrier passes through. Send the amp hour figure printed on the battery you are replacing along with your delivery ZIP, and a specialist confirms the match and quotes it in writing in 24 to 48 hours.

Frequently Asked Questions

Is this the same battery as the Interstate part, or an equivalent?

An equivalent, and we would rather say so plainly. What ships is a CSB EVX12400, a different manufacturer's battery selected because the case dimensions and the terminal match the slot. It is not an Interstate product and it is not built on Interstate's specification. Everything published on this page comes from CSB's own datasheet, so you can check each figure against the source rather than taking our word for the comparison.

What happens if my old battery was rated higher than 40 amp hours?

You get less run between charges, in roughly the ratio of the two numbers. A 50 amp hour block replaced with a 40 gives about four fifths of the previous runtime, and on a mobility chair or a floor machine that is the difference a user notices first. Where the label says more than 40, quote the CSB EVX12520 at 52 amp hours instead. It is a group 22NF case rather than this footprint, so send your tray dimensions and a specialist will confirm which of the two goes in.

Does the threaded insert match what came out?

CSB specifies an I2 insert taking an M6 bolt at 44.9 lbf-in, plus or minus 9.0, while the CSB price list records the standard terminal for this part as B2 / I. Those describe different hardware, so on a cross-reference it is worth settling before the box ships. Send a photo of the connection you are undoing with your quote request and a specialist confirms the build against CSB.

Will it work in a UPS or an alarm panel?

We would point you somewhere else. CSB publishes no float charging voltage for the EVX range and builds it to IEC 60254, the traction standards, which means it is designed to be discharged and recharged rather than held at full charge for years. Standby equipment wants a float rated block. Tell a specialist what the battery powers and you will get the right family rather than the nearest physical match.

The same battery under its own part number: CSB EVX12400Full specifications, cycle figures and the CSB datasheet for the block this page ships.
Not sure the capacity matches?

Send a photo of the label on the battery you are replacing along with the tray dimensions. A specialist confirms the amp hours and the terminal before anything ships, and quotes it in writing.

Call 1-877-775-4381  ·  battery specialists, not a call center

WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov (State of California only).

Customer Reviews

Customers Also Viewed