C&D TEL12-115FN Battery - 12V Front Access Telecom AGM

The TEL12-115FN is a 12V front-access monobloc from C&D's TEL Long Duration line, rated 108 Ah at the 8-hour rate to 1.75 volts per cell. It connects through M6 threaded terminals presented at the face of the case, so a string is built and serviced from the aisle. The TEL series is the standard-AGM side of C&D's telecom catalog, built for the multi-hour reserve discharges a rectifier plant asks for, and C&D publishes a Telcordia-certified life exceeding 10 years for the line.

Warranty

C&D's warranty term for this model is confirmed in writing with your quote. Design life is a separate figure: C&D publishes a Telcordia-certified life exceeding 10 years for the TEL series.

The Long-Duration Workhorse

108 Ah at the 8-hour rate
Rated for the discharge shape telecom plants run: hours of reserve to 1.75 volts per cell, with 106 Ah at the 10-hour rate to 1.80.
Front access, M6 terminals
Connections torque from the face of the case, so intercell work happens without pulling the tray or reaching over live posts.
3.0 milliohm internal resistance
3.0 milliohms, with a 4,000 A short-circuit rating: the two numbers your breaker and cable sizing start from.
  • Standard AGM VRLA construction - sealed and non-spillable, no watering.
  • SR-4228 compliant, UL 1989, UL 1778, UL 924 and UL 94 V-0 - the certification set C&D publishes for the TEL series.
  • Non-hazardous for transport - not restricted for air, surface or water freight per IATA/ICAO Special Provision A67, DOT-CFR and IMDG exception 238.

Technical Specifications

C&D TEL12-115FN Specifications
Part NumberTEL12-115FN (also searched as TEL12 115FN, C&D TEL12-115)
Battery TypeAGM VRLA, front access, long-duration telecom standby
Nominal Voltage12V
Capacity, 8-hour rate108 Ah to 1.75 VPC
Capacity, 10-hour rate106 Ah to 1.80 VPC
Short Circuit Current4,000 A
Internal Resistance0.0030 ohm
Terminal TypeM6 threaded, front access
CertificationsSR-4228, UL 1989, UL 1778, UL 924, UL 94 V-0 (TEL series)
Length20.12 inches (511 mm)
Width4.33 inches (110 mm)
Height9.25 inches (235 mm)
Weight73 lbs (33 kg)
Terminal TorqueM6 at 107 in-lbs (12 N-m)
Operating TemperatureDischarge -40°F to +160°F; charge -10°F to +140°F
Float Charging Voltage13.5 to 13.8 VDC average per 12V unit at 77°F
StorageUp to 6 months at 77°F before a freshening charge is required
Design LifeTelcordia-certified, exceeding 10 years (C&D, TEL series)
WarrantyConfirmed in writing with your quote (C&D)

Where This Battery Is Used

  • Central office -48V strings - the reserve behind the rectifiers, sized in amp hours over hours.
  • Remote terminals and huts - conditioned enclosures where the standard TEL build is the economical fit.
  • Broadband and network powering - long-duration holdover for outside-plant electronics.

Ordering and Freight

At 73 lbs per unit, string orders ship freight pre-paid by LTL to commercial addresses; a residential or limited-access delivery adds $100, which is the liftgate and access charge the carrier bills us. A specialist returns a written quote with volume pricing in 24 to 48 hours.

Frequently Asked Questions

What does a Telcordia-certified life claim?

C&D states the TEL series is Telcordia tested and qualified to meet all SR-4228 requirements, and the life it publishes for the line, exceeding 10 years, carries that certification. Real service life still depends on temperature and float discipline at your site.

Do I need the high-temperature version instead?

Only if the environment says so. In a conditioned central office or a cabinet that stays near 77°F, the standard TEL build carries the duty at a lower cost basis, and buying pure lead headroom the site never uses helps nobody. Where the enclosure bakes in summer or the site skips cooling to save power, the TEL-HT line exists for exactly that, and we will tell you plainly which side of the line your site sits on.

What does sealed VRLA mean for the equipment room?

The electrolyte is held in the glass mat, so there is nothing to spill and nothing to top up. C&D rates gas recombination at 99% plus, fits a flame-arresting one-way pressure-relief vent and uses a UL 94 V-0 case. Its install note calls for at least 0.5 inch (12.5 mm) between units for free-air ventilation, and your install code has the final word.

How long can these sit before installation?

C&D allows up to 6 months at 77°F before a freshening charge is required. Time the delivery to the install date so the string is not waiting on a shelf.

The full C&D telecom catalogTEL long duration, Pure Lead Plus and High Rate Max, sorted by the duty they serve.
Get the TEL12-115FN priced for your string

Send the quantity, your delivery ZIP and your requested-by date. A specialist confirms availability, the warranty term, volume pricing and freight in writing, with no obligation to buy.

Call 1-877-775-4381  ·  battery specialists, not a call center

WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov (State of California only).

Customer Reviews

Customers Also Viewed