DEKA Unigy UPS HR5500 High Rate Series Battery
DEKA Unigy UPS HR5500 High Rate Series Battery
Deka Unigy HR5500 Battery - 12V 550 WPC High Rate UPS AGM
Warranty
550 Watts, Top Terminals
- Leak-tested AGM VRLA - case and cover heat sealed and 100 percent tested, epoxy-sealed posts, micro-porous glass mat separators, flame-arresting self-sealing valves.
- UL 1973 certified - for energy storage applications; construction meets UL recognition requirements and IEEE recommended practices.
- Flame-retardant case - polypropylene rated UL 94 V-0, limiting oxygen index above 28 percent, reinforced to resist bulging.
- 13.50V float per battery - plus or minus 0.5 percent at 77°F, published range 13.42V to 13.57V.
- Factory acceptance testing offered - an optional East Penn discharge at the 10-minute rate to 1.67 VPC with a formal report, worth pricing on a string this size.
Technical Specifications
| Deka Unigy HR5500 Specifications | |
|---|---|
| Part Number | HR5500 (also searched as HR 5500, deka hr5500, unigy hr5500, hr5500 battery) |
| Battery Type | AGM VRLA with IPF plate technology, high rate, top terminal, UPS standby |
| Nominal Voltage | 12V |
| Rating | 550 watts per cell at the 15-minute rate to 1.67 VPC at 77°F; watt-rated, no amp-hour rating is published |
| Constant Power to 1.67 VPC | 1,244 W/cell at 1 min, 914 at 5 min, 694 at 10 min, 550 at 15 min, 459 at 20 min, 345 at 30 min, 199 at 60 min |
| Constant Power to 1.75 VPC | 782 W/cell at 5 min, 622 at 10 min, 504 at 15 min, 196 at 60 min (no 1-minute figure published at this end voltage) |
| Positive Plate | Greater than 98% pure lead, tin-calcium alloy |
| Negative Plate | Pure lead, calcium alloy |
| Terminal Type | Top access, 1/4-20 threaded insert, epoxy-sealed posts |
| Length | 13.46 inches (341.9 mm) |
| Width | 6.84 inches (173.7 mm) |
| Height | 11.21 inches (284.7 mm) |
| Weight | 105.5 lbs (48 kg) |
| Float Charging Voltage | 13.50V per battery ±0.5% at 77°F (range 13.42V to 13.57V) |
| Case Material | Flame-retardant polypropylene, UL 94 V-0, >28% limiting oxygen index |
| Valves | Low positive pressure, self-sealing, flame arrestor |
| Standards | UL 1973; UL recognition; IEEE recommended practices |
| Design Life | 10 years in float applications at 77°F (East Penn) |
| Warranty | 3 years (East Penn, High Rate top terminal tier, Form 0986) |
| Minimum Order | 4 units |
Where This Battery Is Used
- Large three-phase UPS strings - 32 to 40 blocks behind a UPS in the 100 kW class and up, sized on the 15-minute rate.
- Data center and colocation battery rooms - top-post racks at 11.21 inches tall, serviced from above.
- Industrial process ride-through - lines that need minutes of full power to shut down in order or to bridge to a generator.
Ordering and Freight
Frequently Asked Questions
Is there a front-access version of the HR5500?
East Penn publishes an HR5500ET, a 550 watt per cell front-access block on Form 0773, which under Form 0986 would carry the 4-year front-access term. We do not list it as a stock page yet; if your cabinet needs front terminals at this rating, ask for it on the quote request and a specialist prices it from East Penn's document.
Can I put HR5500 blocks where 31HR5000 blocks were?
Physically, yes: the two share the 13.46 by 6.84 by 11.21 inch case and the top quarter-inch 20 inserts, so the tray and the intercell cables carry over. Confirm three things first: that the rack rating takes the extra 8.5 lbs per block, that the charger's current limit suits the new string, and that the UPS is set for the higher-rated battery. Replace the whole string at once rather than mixing the two ratings.
How long does an HR5500 string run at half its 15-minute load?
Read across the table. At 15 minutes the block gives 550 watts per cell; at 30 minutes it gives 345, and at 60 minutes 199, all to 1.67 VPC at 77°F. Runtime does not scale in a straight line with load: a block loaded at half its 15-minute rating, about 275 watts per cell, runs somewhere past 40 minutes on these figures, closer to three times the runtime than two. Send the actual load and a specialist reads the exact point from East Penn's data.
What does the string weigh?
At 105.5 lbs per block, a 40-block string is 4,220 lbs of battery, and a 32-block string 3,376 lbs, before racks and cabling. Floor loading and freight both start from that number. Our quote states the shipped weight and the pallet count so the receiving dock can plan for it.
Send the quantity, your delivery ZIP and your requested-by date. A specialist confirms availability, the warranty term, volume pricing and freight in writing, with no obligation to buy.
Call 1-877-775-4381 · battery specialists, not a call centerWARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov (State of California only).