Free Shipping
Orders $75 & Up
-
30-day Money Back
Guarantee*
-
100% Secure Online Shopping
SSL - Verified Merchant
DEKA Unigy UPS HR3500ET High Rate Series Battery
DEKA Unigy UPS HR3500ET High Rate Series Battery
Deka Unigy HR3500ET Battery - 12V 370 WPC High Rate Front Access
Warranty
Slim Case, Front Terminals
- Sealed AGM construction - valve-regulated, with micro-porous glass mat separators, a heat-sealed case and cover, epoxy-sealed posts and self-sealing flame-arresting valves, every one factory tested.
- UL 1973 for energy storage - carried alongside UL recognition requirements and IEEE recommended practices, per the flyer.
- Flame-retardant polypropylene case - UL 94 V-0, limiting oxygen index above 28 percent.
- Published float band - 13.42V to 13.57V per battery around a 13.50V setting at 77°F.
- Outline drawing to ASME Y14.5 - East Penn's flyer carries the dimensioned drawing, so shelf spacing can be laid out before the blocks arrive.
Technical Specifications
| Deka Unigy HR3500ET Specifications | |
|---|---|
| Part Number | HR3500ET (also searched as HR 3500ET, deka hr3500et, unigy hr3500et; the ET denotes the front-access terminal case) |
| Battery Type | AGM VRLA with IPF plate technology, high rate, front access, UPS standby |
| Nominal Voltage | 12V |
| Rating | 370 watts per cell at the 15-minute rate to 1.67 VPC at 77°F; watt-rated, no amp-hour rating is published |
| Constant Power to 1.67 VPC | 957 W/cell at 1 min, 654 at 5 min, 472 at 10 min, 370 at 15 min, 306 at 20 min, 228 at 30 min, 133 at 60 min |
| Constant Power to 1.75 VPC | 580 W/cell at 5 min, 436 at 10 min, 350 at 15 min, 131 at 60 min (no 1-minute figure published at this end voltage) |
| Positive Plate | Greater than 98% pure lead, tin-calcium alloy |
| Negative Plate | Pure lead, calcium alloy |
| Terminal Type | Front access, 1/4-20 threaded insert, epoxy-sealed posts |
| Length | 19.44 inches (493.8 mm) |
| Width | 4.24 inches (107.7 mm) |
| Height | 9.09 inches (230.8 mm) |
| Weight | 75.5 lbs (34 kg) |
| Float Charging Voltage | 13.50V per battery ±0.5% at 77°F (range 13.42V to 13.57V) |
| Case Material | Flame-retardant polypropylene, UL 94 V-0, >28% limiting oxygen index |
| Valves | Low positive pressure, self-sealing, flame arrestor |
| Standards | UL 1973; UL recognition; IEEE recommended practices |
| Design Life | 10 years in float applications at 77°F (East Penn) |
| Warranty | 4 years (East Penn, High Rate front access tier, Form 0986) |
| Minimum Order | 4 units |
Where This Battery Is Used
- Front-access UPS battery cabinets - shelves of narrow blocks wired from the front, common in modular and lineup-and-match UPS enclosures.
- Telecom and cable headend ride-through - short-duration backup to generator start where the rack is serviced from the aisle.
- Retrofits of narrow front-terminal blocks - the 4.24 inch width matches shelves cut for slim high-rate cases.
Ordering and Freight
Frequently Asked Questions
Why does East Penn give the HR3500ET a year more warranty than the HR3500?
Form 0986 sets the High Rate term by terminal style: 4 years for the front-access ET models and 3 years for top-terminal blocks. The two HR3500 variants share the 370 watt rating and the 10-year design life; the extra year follows the case. If your cabinet accepts either, the ET is the longer-covered choice at 4 lbs more per block.
How many HR3500ET blocks fit on a 24-inch shelf?
Five, if the shelf is a true 24 inches clear and the manufacturer's spacing allows it, since each block is 4.24 inches wide; four with the usual air gap between cases. The 4.97 inch front-access blocks in the Deka range fit four to the same shelf at most. Send the shelf drawing or the cabinet model and a specialist confirms the layout against East Penn's outline drawing.
Why is there no 1-minute rating at 1.75 volts per cell?
East Penn lists it as not available on Form 1552 at the 1.70 and 1.75 VPC rows. A 1-minute discharge at a high end voltage is outside the range the table covers for this block. For 1-minute sizing use the 1.67 VPC row, 957 watts per cell, or the lower end voltages the table does publish. If your UPS specifies 1.75 VPC at one minute, say so and a specialist will check the alternatives rather than guess a number.
Is the HR3500ET a telecom battery or a UPS battery?
It is rated for UPS work, in watts per cell over minutes, and the East Penn form that governs its warranty is the High Rate form. It is used in telecom plant where the requirement is short ride-through to generator start rather than hours of reserve. For an eight-hour reserve string, the amp-hour rated Unigy I blocks such as the 12AVR150ET are the right series; for fifteen minutes at high power from a front-access shelf, this is.
Send the quantity, your delivery ZIP and your requested-by date. A specialist confirms availability, the warranty term, volume pricing and freight in writing, with no obligation to buy.
Call 1-877-775-4381 · battery specialists, not a call centerWARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov (State of California only).