Free Shipping
Orders $75 & Up
-
30-day Money Back
Guarantee*
-
100% Secure Online Shopping
SSL - Verified Merchant
NorthStar NSB100FT Blue+ Front Terminal Telecom Battery
NorthStar NSB100FT Blue+ Front Terminal Telecom Battery
NorthStar NSB100FT BLUE+ Battery - 12V 100Ah Thin Plate AGM, Front Terminal
Warranty
Why the BLUE+ Build Exists
Technical Specifications
| Nominal Voltage | 12V (6 cells) |
| Capacity, 10-Hour Rate | 100 Ah to 1.80 VPC at 77°F (25°C) |
| Capacity, 8-Hour Rate | 100 Ah to 1.75 VPC at 77°F (25°C) |
| Chemistry | AGM thin plate lead (VRLA) |
| Cyclic Performance | 2050 cycles at 50% depth of discharge |
| Impedance (1 kHz) | 5.6 milliohms |
| Short Circuit Current | 2210 A |
| Float Voltage | 2.28 VPC at 68°F (20°C) / 2.27 VPC at 77°F (25°C) |
| Maximum Charge Current | No limit |
| Terminal Type | Front terminal, male M6 threaded post, three-stage design, torque 9.0 Nm (80 in-lbs) |
| Length | 395 mm (15.6 inches) |
| Width | 108 mm (4.3 inches) |
| Height | 288 mm (11.3 inches) |
| Weight | 32.6 kg (72 lbs) |
| Operating Temperature | -40°F to 149°F (-40°C to +65°C) |
| Shelf Life | Up to 24 months |
| Container | Flame retardant to UL94-V0, highly resistant to shock and vibration; non-halogenated thermally sealed casing |
| Transport | Approved as non-hazardous cargo for ground, sea and air |
| Standards | Telcordia SR4228, IEC 60896, Bellcore GR-63-Core; UL approved and UN2800 certified |
| Design Life | 12+ years at 68°F (20°C); 2050 cycles at 50% depth of discharge |
| Warranty | EnerSys term confirmed in writing with your quote |
| Specification Source | NorthStar NSB BLUE+ range summary, AMER-EN-RS-NSB-BLUE+-0525 (EnerSys, 2025), read first-hand; operating range per the NorthStar per-model data sheet, which governs for this line |
Where This Battery Is Used
- Hybrid genset and fuel-saving installations - sites where the engine runs in bursts and the battery carries the gaps, which is the duty the 2050-cycle rating was drawn for.
- Telecom backup on unreliable mains - cabinets and huts that cycle rather than float, where a standby-rated block would age out early.
- Renewable and energy storage plant - solar and wind installations working in partial state of charge for long stretches.
- Central offices and inside plant - -48 volt strings on 19 and 23-inch shelves, where the front-terminal format puts every connection on the aisle side.
Ordering and Freight
Frequently Asked Questions
What warranty does the NSB100FT BLUE+ carry?
The warranty term for the NSB100FT BLUE+ is confirmed in writing with your quote. The figure published on the data sheet is the design life: 12 or more years at 68°F (20°C), with 2050 cycles at 50% depth of discharge. On a cycling site the cycle rating is usually the number that sets replacement timing, so it is the one to compare between suppliers.
What is PSoC cycling, and why does the BLUE+ suit it?
Partial state of charge means the battery spends its working life somewhere between full and empty rather than sitting topped up. Ordinary stationary lead-acid hates that, because sulfation builds on the plates when the battery is rarely brought back to a full charge and the lost capacity does not show up on a float voltage reading. The BLUE+ uses a thin plate pure lead construction and a fast-recharge acceptance that lets it come back up quickly between events, and NorthStar rates it at 2050 cycles to 50% depth of discharge on that basis. In practice: if your site discharges the battery on purpose, on a schedule, this is the line to look at. If it discharges once a year in an outage, you are paying for cycling you will never use.
How do I choose between BLUE+, RED and HT RED?
By duty and by cabinet temperature, not by capacity. BLUE+ is the cycling build with a 12+ year design life, and its warranty term is confirmed with your quote. RED is the float standby build with a 15+ year design life, and EnerSys warrants it for three years. HT RED is the hot-cabinet build, rated for sustained operation at 104°F, and EnerSys warrants it for four years. A cabinet that runs hot shortens the life of a BLUE+ or a RED block, so send how the site uses the battery and how warm the cabinet runs with your quote request, and a specialist will tell you which of the three the install calls for.
Can I add one new block to an aged NSB100FT BLUE+ string?
Rarely a good idea. In a series string the weakest block sets the runtime, so a new block put into an aged string ages down to the string rather than lifting it, and the replacement delivers less than its own sheet says. This bites harder on a cycling application than on a float one, because the mismatch is exercised every cycle rather than once a year. If the string is several years old, the honest answer is usually to plan the whole string and keep the good survivors as spares. Send the install date and the last set of float readings and a specialist will tell you which case you are in before anything is ordered.
Send the quantity, your delivery ZIP and how the site uses the battery - float standby or genuine cycling. A specialist confirms the 15.6 by 4.3 inch footprint against the shelf, checks the terminal hardware against your cabling, and quotes the set with lead time and freight in writing.
Call 1-877-775-4381 · battery specialists, not a call centerWARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov (State of California only).